Oblique-angle tomography: a restructuring algorithm for transaxial tomographic data
- PMID: 6971325
Oblique-angle tomography: a restructuring algorithm for transaxial tomographic data
Abstract
A set of contiguous transaxial tomographic sections obtained with a rotating-camera tomograph represents the full three-dimensional distribution of activity within a volume of the body. Tomographic sections in planes other than the origianl transverse plane can be produced from these data merely by resorting the data appropriately. The paper presents a simple and efficient algorithm for producing tomograms of the heart oriented either at right angles to the long axis of the left ventricle, or parallel to it. Tomograms in these orientations have specific advantages for imaging the heart and avoid some of the limitations seen in comparable tomograms obtained by the seven-pinhole technique.
Similar articles
-
Clinical evaluation of thallium-201 emission myocardial tomography using a rotating gamma camera: comparison with seven-pinhole tomography.J Nucl Med. 1981 Oct;22(10):849-55. J Nucl Med. 1981. PMID: 6974766
-
In vivo simulation of thallium-201 myocardial scintigraphy by seven-pinhole emission tomography.J Nucl Med. 1980 Sep;21(9):821-8. J Nucl Med. 1980. PMID: 6967956
-
Single-photon transaxial emission computed tomography of the heart in normal subjects and in patients with infarction.J Nucl Med. 1979 Jul;20(7):736-40. J Nucl Med. 1979. PMID: 317297
-
[Myocardial scintigraphy].Arch Mal Coeur Vaiss. 1980 Jan;73(1):13-21. Arch Mal Coeur Vaiss. 1980. PMID: 6770778 Review. French.
-
[Positron emission computed tomography].Kokyu To Junkan. 1982 Oct;30(10):993-8. Kokyu To Junkan. 1982. PMID: 6760311 Review. Japanese. No abstract available.
Cited by
-
Quantitative planar and tomographic thallium-201 myocardial perfusion imaging.Cardiovasc Intervent Radiol. 1987;10(6):374-83. doi: 10.1007/BF02577348. Cardiovasc Intervent Radiol. 1987. PMID: 3123063 Review.
-
On the generation of short-axis and radial long-axis slices in thallium-201 myocardial perfusion single-photon emission tomography.Eur J Nucl Med. 1996 Aug;23(8):924-31. doi: 10.1007/BF01084366. Eur J Nucl Med. 1996. PMID: 8753681
-
Improved detection of myocardial infarction by emission computed tomography with thallium-201. Relation to infarct size.Br Heart J. 1984 Dec;52(6):621-7. doi: 10.1136/hrt.52.6.621. Br Heart J. 1984. PMID: 6334533 Free PMC article.
-
Segmental analysis of stress thallium myocardial emission tomography for localization of coronary artery disease.Eur J Nucl Med. 1984;9(3):99-105. doi: 10.1007/BF00253509. Eur J Nucl Med. 1984. PMID: 6609076
-
Automatic detection of the left ventricular myocardium long axis and center in thallium-201 single photon emission computed tomography.Eur J Nucl Med. 1992;19(12):1032-7. doi: 10.1007/BF00180864. Eur J Nucl Med. 1992. PMID: 1464355
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources