[Low frequency electro-stimulation and ultrasonic therapy (author's transl)]
- PMID: 6974441
- DOI: 10.1055/s-2008-1051434
[Low frequency electro-stimulation and ultrasonic therapy (author's transl)]
Abstract
In a prospective study 1200 sequences of low frequency electrostimulation and ultrasonic therapy have been examined. The basics of the type of currents applied, the therapy scheme and the indication routine are presented. These parameters were kept constant in the course of the 2 years' study. For the treatment 8 different apparatuses were available. The actual current shapes of the generators were measured, the influence of constant-current and constant-voltage output circuits were tested and were discussed in relation to the electrode types.--Advantages and disadvantages of disposable-type, sponge-type, lead-type and vacuum-type electrodes are reported. Treatments were carried out with the current types DF and CP of the diadynamic currents alone, as combined therapy together with ultrasound, as mere ultrasound treatment, as ultrastimulation current, as iontophoresis and galvanic current. The results are compared with comparable examinations by other authors and they are discussed with respect to different influencing factors.
Similar articles
-
Current distribution under electrodes in relation to stimulation current and skin blood flow: are modern electrodes really providing the current distribution during stimulation we believe they are?J Med Eng Technol. 2006 Nov-Dec;30(6):368-81. doi: 10.1080/03091900500183855. J Med Eng Technol. 2006. PMID: 17060165
-
Combined electric field and ultrasound therapy as a novel anti-tumour treatment.Eur J Cancer. 2005 Jun;41(9):1339-48. doi: 10.1016/j.ejca.2005.01.025. Eur J Cancer. 2005. PMID: 15913991
-
[The combined use of sinusoidal modulated currents and ultrasound in patients with adductor contracture of the shoulder joint].Vopr Kurortol Fizioter Lech Fiz Kult. 1995 Sep-Oct;(5):40-1. Vopr Kurortol Fizioter Lech Fiz Kult. 1995. PMID: 8597220 Russian. No abstract available.
-
Uniformity of current density under stimulating electrodes.Crit Rev Biomed Eng. 1990;17(6):585-619. Crit Rev Biomed Eng. 1990. PMID: 2180634 Review.
-
[About optimized designs and circuits of autonomous electric stimulators for the gastrointestinal tract].Med Tekh. 2004 Nov-Dec;(6):34-8. Med Tekh. 2004. PMID: 15656414 Review. Russian.
Cited by
-
Transcutaneous electrostimulation for osteoarthritis of the knee.Cochrane Database Syst Rev. 2009 Oct 7;2009(4):CD002823. doi: 10.1002/14651858.CD002823.pub2. Cochrane Database Syst Rev. 2009. PMID: 19821296 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous