Clinical evaluation of a new fiberoptic catheter oximeter during cardiac surgery
- PMID: 6979954
Clinical evaluation of a new fiberoptic catheter oximeter during cardiac surgery
Abstract
A new pulmonary arterial catheter (Opticath), containing the standard pulmonary artery catheter features plus two fiberoptic filaments to permit continuous measurement of oxygen saturation (SVO2) by a companion oximeter, was studied in 13 patients undergoing elective coronary bypass surgery. The study was designed to evaluate the accuracy of Opticath SVO2 measurements, to determine the incidence of catheter-related problems, and to correlate changes in SVO2 with hemodynamic changes. A good correlation was found between the SVO2 determined by the Opticath and that measured by American Optical and Radiometer Oximeters (r = 0.92 and 0.89 respectively; p less than 0.0001). There was a significant correlation between increases or decreases in values of SVO2 greater than or equal to 5% and corresponding changes in cardiac index, stroke index, and left ventricular stroke work index (p less than 0.001), and an 86% probability that SVO2 decrease greater than or equal to 5% reflected a significant decline in cardiac index.
Similar articles
-
Continuous mixed venous oxygen saturation measurement: a significant advance in hemodynamic monitoring?J Clin Monit. 1985 Oct;1(4):245-58. doi: 10.1007/BF02832818. J Clin Monit. 1985. PMID: 3938481 Review.
-
Continuous monitoring of mixed venous oxygen saturation in critically ill patients.Anesth Analg. 1982 Jun;61(6):513-7. Anesth Analg. 1982. PMID: 7200741
-
Clinical implications of intraoperative continuous mixed venous oxygen saturation monitoring.AANA J. 1989 Feb;57(1):45-52. AANA J. 1989. PMID: 2929243
-
[Continuous measurement of cardiac output based on the Fick principle in cardiac anesthesia].Anaesthesist. 1990 Jan;39(1):13-21. Anaesthesist. 1990. PMID: 2305947 German.
-
[Extensive indications for the use of Swan-Ganz catheter in anesthesia and intensive therapy in the field of cardiac surgery].Minerva Anestesiol. 1987 Apr;53(4):155-64. Minerva Anestesiol. 1987. PMID: 3306458 Review. Italian. No abstract available.
Cited by
-
Wireless, implantable catheter-type oximeter designed for cardiac oxygen saturation.Sci Adv. 2021 Feb 10;7(7):eabe0579. doi: 10.1126/sciadv.abe0579. Print 2021 Feb. Sci Adv. 2021. PMID: 33568482 Free PMC article.
-
Continuous venous oximetry in surgical patients.Ann Surg. 1986 Mar;203(3):329-33. doi: 10.1097/00000658-198603000-00020. Ann Surg. 1986. PMID: 3954486 Free PMC article.
-
Continuous monitoring of mixed venous oxygen saturation in infants after cardiac surgery.Intensive Care Med. 1989;15(4):228-32. doi: 10.1007/BF00271056. Intensive Care Med. 1989. PMID: 2745866
-
Continuous monitoring of mixed venous oxygen saturation in septic shock.J Clin Monit. 1986 Oct;2(4):237-45. doi: 10.1007/BF02851172. J Clin Monit. 1986. PMID: 3097269
-
Continuous mixed venous oxygen saturation measurement: a significant advance in hemodynamic monitoring?J Clin Monit. 1985 Oct;1(4):245-58. doi: 10.1007/BF02832818. J Clin Monit. 1985. PMID: 3938481 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical