Comparative study of thallium emission myocardial tomography with 180 degrees and 360 degrees data collection
- PMID: 6980970
Comparative study of thallium emission myocardial tomography with 180 degrees and 360 degrees data collection
Abstract
Basic and clinical evaluation of thallium single-photon emission computed tomography (SPECT) using a rotating gamma camera with 180 degrees (LPO to RAO) data collection was carried out and compared with the full 360 degrees rotation. No attenuation correction was used. In a phantom study the reconstructed image from the 180 degrees scan revealed better resolution. Although the 180 degrees scan, when compared with the 360 degrees scan, showed great photon attenuation in the deep location of a line source in water, this problem was not significant in the clinical study of six normal hearts. In 11 cases with myocardial infarction, the perfusion defect was more clearly visualized in the 180 degrees scan. The defect-to-normal (D/N) wall-count ratio was lower in the 180 degrees scan (0.48 +/- 0.16; mean +/- s.d.) than in the 360 degrees scan (0.61 +/- 15, p less than 0.05), indicating superior lesion contrast in the former. These results suggest that for myocardial SPECT the 180 degrees collection method is a more effective technique in the clinical evaluation of coronary artery disease.
Similar articles
-
Comparison of 180 degrees and 360 degrees data collection in thallium-20 1 imaging using single-photon emission computerized tomography (SPECT): concise communication.J Nucl Med. 1982 Aug;23(8):655-60. J Nucl Med. 1982. PMID: 6980969
-
Clinical evaluation of thallium-201 emission myocardial tomography using a rotating gamma camera: comparison with seven-pinhole tomography.J Nucl Med. 1981 Oct;22(10):849-55. J Nucl Med. 1981. PMID: 6974766
-
[Application of a rotating gamma camera to cardiac imaging. (3) Evaluation of thallium ECT (emission computed tomography) by a 180 degree rotation data collection method].Kaku Igaku. 1982 May;19(4):535-40. Kaku Igaku. 1982. PMID: 6982361 Japanese. No abstract available.
-
Evaluation of myocardial perfusion and function by single photon emission computed tomography.Semin Nucl Med. 1987 Jul;17(3):200-13. doi: 10.1016/s0001-2998(87)80034-x. Semin Nucl Med. 1987. PMID: 3303340 Review.
-
Thallium imaging with single photon emission computed tomography.Am Heart J. 1987 Oct;114(4 Pt 1):852-65. doi: 10.1016/0002-8703(87)90796-4. Am Heart J. 1987. PMID: 3310567 Review.
Cited by
-
Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man.Br Heart J. 1984 Jul;52(1):30-7. doi: 10.1136/hrt.52.1.30. Br Heart J. 1984. PMID: 6331479 Free PMC article.
-
Target localization using scanner-acquired SPECT data.J Appl Clin Med Phys. 2012 May 10;13(3):3724. doi: 10.1120/jacmp.v13i3.3724. J Appl Clin Med Phys. 2012. PMID: 22584168 Free PMC article.
-
Cardiac single photon emission computerized tomography: the critical period.Int J Card Imaging. 1985;1(2):127-42. doi: 10.1007/BF01884102. Int J Card Imaging. 1985. PMID: 3916433 Review. No abstract available.
-
Clinical comparison of 180-degree and 360-degree data collection of technetium 99m sestamibi SPECT for detection of coronary artery disease.J Nucl Cardiol. 1998 Jan-Feb;5(1):14-8. doi: 10.1016/s1071-3581(98)80005-6. J Nucl Cardiol. 1998. PMID: 9504868 Clinical Trial.
-
Improved detection of myocardial infarction by emission computed tomography with thallium-201. Relation to infarct size.Br Heart J. 1984 Dec;52(6):621-7. doi: 10.1136/hrt.52.6.621. Br Heart J. 1984. PMID: 6334533 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources