Implant-bone interface characteristics of bioglass dental implants
- PMID: 6987233
- DOI: 10.1002/jbm.820140104
Implant-bone interface characteristics of bioglass dental implants
Abstract
Three-dimensional finite element analysis (FEA) has been used to determine the implant-bone interface characteristics of bioglass dental implants. The results of the FEA were verified by comparison with the results of mechanical testing performed on animal implant specimens. The results of the study showed that the assumption of a discontinuous change of elastic properties at the bone-implant interface was a poor assumption for the bioglass implants. Interface elastic moduli of 354.0, 155.0, and 47.0 MPa for conditions of 25, 50, and 100% tissue attachment were determined for the bioglass implants.
Similar articles
-
Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures.Int J Prosthodont. 2007 Mar-Apr;20(2):193-8. Int J Prosthodont. 2007. PMID: 17455444
-
Quantitative histologic evaluation of LTI carbon, carbon-coated aluminum oxide and uncoated aluminum oxide dental implants.J Biomed Mater Res. 1983 May;17(3):519-38. doi: 10.1002/jbm.820170311. J Biomed Mater Res. 1983. PMID: 6863353
-
Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.J Prosthodont. 2009 Jul;18(5):393-402. doi: 10.1111/j.1532-849X.2009.00453.x. Epub 2009 Apr 3. J Prosthodont. 2009. PMID: 19374710
-
Application of finite element analysis in implant dentistry: a review of the literature.J Prosthet Dent. 2001 Jun;85(6):585-98. doi: 10.1067/mpr.2001.115251. J Prosthet Dent. 2001. PMID: 11404759 Review.
-
Biomaterials and biomechanics in dental implant design.Int J Oral Maxillofac Implants. 1988 Summer;3(2):85-97. Int J Oral Maxillofac Implants. 1988. PMID: 3075195 Review. No abstract available.
Cited by
-
Effect of revascularisation and apexification procedures on biomechanical behaviour of immature maxillary central incisor teeth: a three-dimensional finite element analysis study.Clin Oral Investig. 2021 Dec;25(12):6671-6679. doi: 10.1007/s00784-021-03953-1. Epub 2021 Apr 26. Clin Oral Investig. 2021. PMID: 33899155
-
Finite element analysis of stress in mandibular molars repaired after fractured instrument removal.BMC Oral Health. 2025 Jan 17;25(1):85. doi: 10.1186/s12903-025-05464-x. BMC Oral Health. 2025. PMID: 39825336 Free PMC article.
-
Bioglass: A novel biocompatible innovation.J Adv Pharm Technol Res. 2013 Apr;4(2):78-83. doi: 10.4103/2231-4040.111523. J Adv Pharm Technol Res. 2013. PMID: 23833747 Free PMC article.
-
Finite element analysis of sagittal screw expander appliance in the treatment of anterior maxillary hypoplasia.Front Bioeng Biotechnol. 2023 Oct 26;11:1245764. doi: 10.3389/fbioe.2023.1245764. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 37965052 Free PMC article.
-
The story of Bioglass.J Mater Sci Mater Med. 2006 Nov;17(11):967-78. doi: 10.1007/s10856-006-0432-z. Epub 2006 Nov 22. J Mater Sci Mater Med. 2006. PMID: 17122907
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources