Clinical comparison of the (polymacon) spin-cast hydrogel contact lens to the (polymacon) lathe-cut hydrogel lenses
- PMID: 7006402
- DOI: 10.1097/00006324-198008000-00006
Clinical comparison of the (polymacon) spin-cast hydrogel contact lens to the (polymacon) lathe-cut hydrogel lenses
Abstract
The purpose of this study was to compare the clinical acceptability of polymacon spin-cast to polymacon lathe-cut hydrophilic contact lenses. Ten patients successfully wearing polymacon spin-cast lenses were studied. Each patient had one eye refitted with polymacon lathe-cut lenses. Comparison of the two types of lenses was then made. Objective evaluation included centration, movement, visual acuity, and over-refraction. Subjective criteria were based on patient comfort and stability and quality of vision. Results indicate that lathe-cut lenses can be just as clinically satisfactory as the spincast ones.