Algorithms for adjustment of insulin dosage by patients who monitor blood glucose
- PMID: 7011749
- DOI: 10.2337/diacare.4.2.311
Algorithms for adjustment of insulin dosage by patients who monitor blood glucose
Abstract
Patient self-monitoring of blood glucose is a useful adjuvant to diabetes therapy that facilitates improved glycemic control when used as part of an intensive diabetes management program that includes careful balancing of food intake, energy expenditure, and insulin dosage. This paper describes an approach by which patient-determined blood glucose measurements may be used to attain and maintain glycemic control. The patient is provided with a set of algorithms by which minor adjustments in a therapeutic routine may be made to achieve the desired control.
Similar articles
-
Compliance in microcomputer-assisted conventional insulin therapy: computer simulation study results.Am J Physiol. 1988 Feb;254(2 Pt 1):E237-42. doi: 10.1152/ajpendo.1988.254.2.E237. Am J Physiol. 1988. PMID: 3279805
-
Frequent insulin dosage adjustments based on glucose readings alone are sufficient for a safe and effective therapy.J Diabetes Complications. 2012 May-Jun;26(3):230-6. doi: 10.1016/j.jdiacomp.2012.03.012. Epub 2012 Apr 20. J Diabetes Complications. 2012. PMID: 22521317 Clinical Trial.
-
Self blood glucose monitoring: an adjunct to dietary and insulin management of the patient with diabetes.J Am Diet Assoc. 1987 Jan;87(1):61-5. J Am Diet Assoc. 1987. PMID: 3540076
-
Diabetes: the latest trends in glycemic control.Clin Podiatr Med Surg. 2007 Apr;24(2):159-89. doi: 10.1016/j.cpm.2006.12.001. Clin Podiatr Med Surg. 2007. PMID: 17430766 Review.
-
Effective use of insulin. A balancing act.Postgrad Med. 1994 Jun;95(8):52-4, 58-60, 63-4 passim. Postgrad Med. 1994. PMID: 8202423 Review.
Cited by
-
Dealing with ceiling baseline treatment satisfaction level in patients with diabetes under flexible, functional insulin treatment: assessment of improvements in treatment satisfaction with a new insulin analogue.Qual Life Res. 2000;9(8):915-30. doi: 10.1023/a:1008921419108. Qual Life Res. 2000. PMID: 11284211
-
Use of Automated Bolus Calculators for Diabetes Management.Eur Endocrinol. 2013 Aug;9(2):92-95. doi: 10.17925/EE.2013.09.02.92. Epub 2013 Aug 23. Eur Endocrinol. 2013. PMID: 29922360 Free PMC article. Review.
-
A Run-to-Run Control Strategy to Adjust Basal Insulin Infusion Rates in Type 1 Diabetes.J Process Control. 2008;18(3-4):258-265. doi: 10.1016/j.jprocont.2007.07.010. J Process Control. 2008. PMID: 18709180 Free PMC article.
-
Management of diabetics with the use of a microprocessor: comparison of insulin treatments based on blood and urine glucose levels.Acta Diabetol Lat. 1988 Jan-Mar;25(1):33-40. doi: 10.1007/BF02581243. Acta Diabetol Lat. 1988. PMID: 3043988
-
Automatic data processing to achieve a safe telemedical artificial pancreas.J Diabetes Sci Technol. 2009 Sep 1;3(5):1039-46. doi: 10.1177/193229680900300507. J Diabetes Sci Technol. 2009. PMID: 20144417 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical