Ultrasonography of prosthetic cardiac valves
- PMID: 7014103
Ultrasonography of prosthetic cardiac valves
Abstract
Although many cases of prosthetic valve malfunction have appeared in the literature, statistically significant reports of the noninvasive diagnosis of valve malfunction are few. Metal-and-plastic mitral valves may be evaluated by a combined echocardiographic and phonocardiographic approach. Analysis of the A2-MVO interval seems to provide the most amount of information; supportive data useful in identifying the cause of valve malfunction come from phonocardiographic murmur and echocardiographic wall motion analysis. Additional cases of valve dysfunction will be detected if spectral analysis and cinefluoroscopy are also used. Suspected cases of mitral prosthetic malfunction must always be differentiated from left ventricular dysfunction; this may require invasive study. There is no evidence that two-dimensional echocardiography has any use in the analysis of metal-and-plastic mitral valves. There is no evidence that any noninvasive technique, particularly echocardiography, can consistently detect metal-and-plastic aortic prosthesis malfunction, especially of the tilting-disc type of valve. Noninvasive evaluation of tissue heterograft valves in the mitral and aortic positions require combined M-mode and two-dimensional echocardiographic study. Morphologic and functional alteration in these valves can be detected. Most importantly, accurate analysis of any particular valve requires an understanding of the individual clinical setting.
Similar articles
-
Echophonocardiographic evaluation of normal and abnormal prosthetic valve function.Cardiovasc Clin. 1983;13(3):117-45. Cardiovasc Clin. 1983. PMID: 6349800 Review.
-
Noninvasive evaluation of cardiac valve prostheses.Cardiovasc Clin. 1986;17(1):201-41. Cardiovasc Clin. 1986. PMID: 3768920
-
Non-invasive assessment of the Ionescu-Shiley pericardial xenograft heart valve.Can J Cardiol. 1985 Jul-Aug;1(4):241-50. Can J Cardiol. 1985. PMID: 3850772
-
[M-mode and two-dimensional echocardiographic features of porcine xenograft valve dysfunction].J Cardiogr. 1982 Mar;12(1):33-44. J Cardiogr. 1982. PMID: 7119497 Japanese.
-
Echocardiographic and phonocardiographic evaluation of prosthetic heart valves.Cardiovasc Clin. 1978;9(2):187-207. Cardiovasc Clin. 1978. PMID: 359146 Review. No abstract available.
Cited by
-
Echocardiography in mitral valve disease: a review.Int J Card Imaging. 1985;1(3):189-205. doi: 10.1007/BF01784205. Int J Card Imaging. 1985. PMID: 3916435 Review.