Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1980 Aug;12(2):185-92.
doi: 10.1128/jcm.12.2.185-192.1980.

Enzyme-linked immunosorbent assay for titration of Haemophilus influenzae capsular and O antigen antibodies

Comparative Study

Enzyme-linked immunosorbent assay for titration of Haemophilus influenzae capsular and O antigen antibodies

T Dahlberg et al. J Clin Microbiol. 1980 Aug.

Abstract

The enzyme-linked immunosorbent assay (ELISA) was elaborated for the detection of immunoglobulin M (IgM) and IgG antibodies against capsular and O antigens of Haemophilus influenzae. Purified capsular polysaccharide and lipopolysaccharide were used as antigens, with optimal coating concentrations being about 50 and 100 micrograms/ml, respectively. The antibody content was expressed as the highest serum dilution (-log10) showing an absorbance of 0.2 above the background level. The titers of hyperimmune sera (reference sera) ranged between 5 and 7 -log10. The sensitivity of the method was about 80 ng/ml with regard to anticapsular antibodies and 3 to 5 ng/ml with regard to anti-lipopolysaccharide antibodies. For detection of antibodies against capsular polysaccharide in sera obtained after primary immunization, ELISA was about 100-fold more sensitive than the indirect hemagglutination assay, whereas in hyperimmune sera, ELISA was about 10-fold more sensitive than the indirect hemagglutination assay. The sensitivity of ELISA for detecting anticapsular antibodies after primary and booster immunizations was 50-fold higher than that of the bactericidal assay using capsulated bacteria, whereas the sensitivity of the two methods was the same when hyperimmune sera were tested. ELISA performed with lipopolysaccharide as the antigen was about 50- and 150-fold more sensitive than the complement fixation and bactericidal assays tested with noncapsulated variants after primary injection and hyperimmunization, respectively.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Immunol. 1972 Jun;108(6):1551-62 - PubMed
    1. Acta Pathol Microbiol Scand B Microbiol Immunol. 1972;80(2):211-20 - PubMed
    1. J Immunol. 1972 Jul;109(1):129-35 - PubMed
    1. Infect Immun. 1972 Nov;6(5):703-8 - PubMed
    1. Int Arch Allergy Appl Immunol. 1972;43(4):533-47 - PubMed

Publication types

LinkOut - more resources