Evaluation of twenty-three blood culture media
- PMID: 701464
- PMCID: PMC275233
- DOI: 10.1128/jcm.8.3.288-292.1978
Evaluation of twenty-three blood culture media
Abstract
Several investigators have evaluated clinically a variety of commercially available blood culture media. No agreement has been reached as to which of these media is optimal for detection of bacteremia. The purpose of this study was to determine the rate of recovery of microorganisms from various blood culture media. A total of 23 blood culture media were inoculated with 7 to 15 microorganisms per bottle in the presence or absence of an erythrocyte-serum mixture. The results demonstrated that blood culture media differed in their ability to support the growth of microorganisms. At 4 days after inoculation, only 10 of the 23 blood culture media supported the growth of 91% (10 of the 11) or more of the test microorganisms. The recovery rate of microorganisms depended not only upon the type of medium but also upon the manufacturer of the type of blood culture medium. The addition of an erythrocyte-serum mixture to the blood culture media did not influence the difference in the recovery rate of microorganisms among media and the same type of medium prepared by different manufacturers. The majority (15 of the 23) of the blood culture media supplemented with the erythrocyte-serum mixture failed to support the growth of 91% or more of the test microorganisms at 4 days after inoculation. These results have demonstrated that blood culture media need to be improved. Better quality control measures should also be implemented to evaluate commercial blood culture media.
Similar articles
-
Evaluation of ten anaerobic blood culture media.Am J Clin Pathol. 1979 Aug;72(2):199-203. doi: 10.1093/ajcp/72.2.199. Am J Clin Pathol. 1979. PMID: 382828
-
Comparison of the BACTEC MYCO/F Lytic bottle to the isolator tube, BACTEC Plus Aerobic F/bottle, and BACTEC Anaerobic Lytic/10 bottle and comparison of the BACTEC Plus Aerobic F/bottle to the Isolator tube for recovery of bacteria, mycobacteria, and fungi from blood.J Clin Microbiol. 2001 Dec;39(12):4380-6. doi: 10.1128/JCM.39.12.4380-4386.2001. J Clin Microbiol. 2001. PMID: 11724848 Free PMC article.
-
Controlled comparison of the BACTEC high-blood-volume fungal medium, BACTEC Plus 26 aerobic blood culture bottle, and 10-milliliter isolator blood culture system for detection of fungemia and bacteremia.J Clin Microbiol. 1993 Apr;31(4):865-71. doi: 10.1128/jcm.31.4.865-871.1993. J Clin Microbiol. 1993. PMID: 8463399 Free PMC article.
-
Rapid detection and identification of microorganisms from blood cultures.Clin Lab Med. 1994 Mar;14(1):181-95. Clin Lab Med. 1994. PMID: 8181231 Review.
-
Laboratory detection of fungemia.Clin Lab Med. 1994 Mar;14(1):83-97. Clin Lab Med. 1994. PMID: 8181236 Review.
Cited by
-
Detection time for blood culture isolates using a biphasic medium.Eur J Clin Microbiol. 1983 Feb;2(1):54-5. doi: 10.1007/BF02019926. Eur J Clin Microbiol. 1983. PMID: 6341052 No abstract available.
-
Growth of Haemophilus influenzae in simulated blood cultures supplemented with hemin and NAD.J Clin Microbiol. 1983 Aug;18(2):376-9. doi: 10.1128/jcm.18.2.376-379.1983. J Clin Microbiol. 1983. PMID: 6604736 Free PMC article.
-
Detection and quantitation of simulated anaerobic bacteremia by centrifugation and filtration.J Clin Microbiol. 1983 May;17(5):856-9. doi: 10.1128/jcm.17.5.856-859.1983. J Clin Microbiol. 1983. PMID: 6863505 Free PMC article.
-
Blood cultures: where do we stand?J Clin Pathol. 1988 Jun;41(6):668-70. doi: 10.1136/jcp.41.6.668. J Clin Pathol. 1988. PMID: 3290271 Free PMC article. Review. No abstract available.
-
Recovery of Haemophilus influenzae from twenty-three blood culture media.J Clin Microbiol. 1979 Jan;9(1):84-7. doi: 10.1128/jcm.9.1.84-87.1979. J Clin Microbiol. 1979. PMID: 311778 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources