Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1981 May;193(5):628-37.
doi: 10.1097/00000658-198105000-00014.

Intraoperative determination of small intestinal viability following ischemic injury: a prospective, controlled trial of two adjuvant methods (Doppler and fluorescein) compared with standard clinical judgment

Clinical Trial

Intraoperative determination of small intestinal viability following ischemic injury: a prospective, controlled trial of two adjuvant methods (Doppler and fluorescein) compared with standard clinical judgment

G B Bulkley et al. Ann Surg. 1981 May.

Abstract

Two adjuvant techniques for the intraoperative assessment of small intestinal viability were compared with standard clinical judgment in a prospective, controlled study of 71 ischemic bowel segments in 28 consecutive patients operated on for acute intestinal ischemic disease. Each segment was independently assessed 15 minutes after surgical correction of the underlying lesion by: 1) standard clinical judgment; 2) Doppler-detected pulsatile mural blood flow; and 3) fluorescein ultraviolet fluorescence pattern. Viability endpoint for each segment was determined objectively by patient follow-up or "blinded" microscopic evaluation of histologically unequivocal resection specimens using criteria established by previous animal studies. Seventeen histologically equivocal specimens were excluded from the final results. Standard clinical judgment proved moderately accurate overall (89%) but would have led to a relatively high rate (46%) of unnecessary bowel resection. The Doppler technique did not increase accuracy in any category of evaluation. The fluorescein fluorescent pattern was correct in all 54 determinant bowel segments, and proved more sensitive specific, predictive, and significantly more accurate overall than either standard clinical judgment or the Doppler method. This controlled study suggests that the fluorescein technique is the method of choice for the prediction of small intestinal recovery following ischemic injury.

PubMed Disclaimer

References

    1. Surgery. 1967 Nov;62(5):899-909 - PubMed
    1. Am J Surg. 1981 Jan;141(1):128-35 - PubMed
    1. Surg Gynecol Obstet. 1969 Jan;128(1):97-102 - PubMed
    1. Ann Surg. 1972 Jul;176(1):97-101 - PubMed
    1. Am J Surg. 1974 Feb;127(2):136-41 - PubMed

Publication types

LinkOut - more resources