. 1982 Feb;45(2):256-64.
doi: 10.1038/bjc.1982.41.

Oxygen tensions in multicell spheroids of two cell lines

Free PMC article

Oxygen tensions in multicell spheroids of two cell lines

W F Mueller-Klieser et al. Br J Cancer. 1982 Feb.
Free PMC article

Abstract

O2 tensions (Po2) were measured with microelectrodes in multicellular spheroids from EMT6/Ro and V-79-171-B cells. The measurements were performed in spheroids kept in flowing growth medium that was equilibrated with 5% CO2 and air at a temperature of 37 degrees C and contained 5.5 mM glucose. The recorded Po2 profiles are characterized by a diffusion-depleted zone surrounding the spheroids and by a steep drop in Po2 within the spheroids over mean distance of 220 and 188 micrometer from the surface of EMT6/Ro and V-79-171B spheroids over mean distance of 220 and 188 micrometer from the surface of EMT6/Ro and V-79-171B spheroids respectively. Smaller spheroid exhibit parabolic Po2 profiles, larger ones show a central plateau. The region of the steep decrease in Po2 corresponds to the thickness of the viable rim: the plateau region is created by the absence of O2 consumption in the central necrotic area. Po2 in the centre of EMT6/Ro spheroids decreased from 66 mmHg at a diameter of 400 micrometer to 13 mmHg at a diameter of 1000 micrometer. Under the present conditions during growth and in the experiments, values below 5 mmHg were recorded only in spheroids 1200 micrometer. Comparably low Po2 was recorded in V-79 spheroids with diameters of 650 micrometer +. In spheroids of this cell type with a diameter of 400 micrometer, Po2 was 42 mmHg. The findings provide evidence that necrosis may arise at average Po2 of 57 and 42 mmHg in EMT6/Ro and V-79-171B spheroids, respectively, grown under the conditions described.

PubMed Disclaimer

References

    1. Microvasc Res. 1979 Mar;17(2):181-91 - PubMed
    1. J Biol Chem. 1976 Sep 25;251(18):5630-6 - PubMed
    1. J Appl Physiol Respir Environ Exerc Physiol. 1978 Jul;45(1):145-54 - PubMed
    1. Radiat Res. 1979 Sep;79(3):454-67 - PubMed
    1. Br J Cancer Suppl. 1978 Jun;3:163-7 - PubMed

Publication types