Measurement of coronary sinus blood flow by fiber-optic laser Doppler anemometry
- PMID: 7091350
- DOI: 10.1152/ajpheart.1982.242.6.H1111
Measurement of coronary sinus blood flow by fiber-optic laser Doppler anemometry
Abstract
The Doppler shift of a laser has been used to measure the velocity of blood in the coronary sinus of the dog. The laser was delivered along a fine fiber-optic probe, which was also used to receive the reflected light. The Doppler shift was measured from the output of a digital spectrum analyzer. This measurement, proportional to the velocity of blood, was correlated with the blood flow measured by an electromagnetic flowmeter. Studies were performed on 112 successful maneuvers in eight consecutive anesthetized dogs. In the minimally damped electromagnetic flow traces, the correlation between coronary sinus blood flow velocity and coronary sinus blood flow was high (r greater than 0.95). This measurement will give absolute flow values only if the exact dimensions of the coronary sinus are known. The linear relationship of coronary sinus velocity and flow supports the postulate that coronary sinus dimension remains similar during normal and high flows. This technique, fiber-optic laser Doppler anemometry, is an accurate measure of relative coronary sinus blood flow. It is suitable for use in human coronary sinuses, especially to monitor the effect of interventions.
Similar articles
-
A laser Doppler catheter for monitoring both phasic and mean coronary vein flow.Heart Vessels. 1990;6(1):1-8. doi: 10.1007/BF02301875. Heart Vessels. 1990. PMID: 2149723
-
Measurement of point velocity in the canine coronary artery by laser Doppler velocimeter with optical fiber.Jpn J Surg. 1981;11(4):226-31. doi: 10.1007/BF02468760. Jpn J Surg. 1981. PMID: 6457195
-
Blood velocity measurement by fiber optic laser Doppler anemometry.IEEE Trans Biomed Eng. 1982 Feb;29(2):142-5. doi: 10.1109/TBME.1982.325021. IEEE Trans Biomed Eng. 1982. PMID: 7056558 No abstract available.
-
Fibre optic laser Doppler measurement of intravascular velocity.Australas Phys Eng Sci Med. 1988 Jan-Mar;11(1):5-14. Australas Phys Eng Sci Med. 1988. PMID: 2977939 Review. No abstract available.
-
[In vivo measurement of ocular circulation with the laser speckle method--development of apparatus and application in ophthalmological research].Nippon Ganka Gakkai Zasshi. 1999 Dec;103(12):871-909. Nippon Ganka Gakkai Zasshi. 1999. PMID: 10643292 Review. Japanese.
Cited by
-
Evaluation of phasic blood flow velocity in the great cardiac vein by a laser Doppler method.Heart Vessels. 1985 Feb;1(1):16-23. doi: 10.1007/BF02066482. Heart Vessels. 1985. PMID: 2936713
-
A laser Doppler catheter for monitoring both phasic and mean coronary vein flow.Heart Vessels. 1990;6(1):1-8. doi: 10.1007/BF02301875. Heart Vessels. 1990. PMID: 2149723
MeSH terms
LinkOut - more resources
Full Text Sources