Pneumococcal sepsis with false-negative blood cultures
- PMID: 7113973
- DOI: 10.1093/ajcp/78.3.348
Pneumococcal sepsis with false-negative blood cultures
Abstract
Most physicians recognize the false-positive blood cultures (generally due to contamination) are common. Bacteria such as pneumococci, however, may rapidly die in broth cultures, and viable bacteria may not be identified. Several patients were observed with pneumococcal infections that had false-negative blood cultures 24 hours after inoculation. Hemolysis and methemoglobin formation in the bottle suggested bacterial growth within 12 hours after incubation, and blind subcultures at that time yielded pneumococci. Pneumococcal antigen could be detected in the blood culture bottles using counter-immunoelectrophoresis, even though subculture at 24 hours yielded no growth. Physicians and laboratory personnel should be aware that false-negative blood cultures may occur, particularly with certain bacteria such as Streptococcus pneumoniae, and that the blood culture bottles should be observed visually for the presence of brown sediment or hemolysis.
Similar articles
-
Avoidance of false-negative blood culture results by rapid detection of pneumococcal antigen.JAMA. 1984 Oct 5;252(13):1742-3. JAMA. 1984. PMID: 6471302
-
Streptococcus pneumoniae antigen test using positive blood culture bottles as an alternative method to diagnose pneumococcal bacteremia.J Clin Microbiol. 2005 May;43(5):2510-2. doi: 10.1128/JCM.43.5.2510-2512.2005. J Clin Microbiol. 2005. PMID: 15872298 Free PMC article.
-
Pneumococcal antigen testing of blood culture broth to enhance the detection of Streptococcus pneumoniae bacteremia.Eur J Clin Microbiol Infect Dis. 2012 May;31(5):753-6. doi: 10.1007/s10096-011-1370-3. Epub 2011 Aug 7. Eur J Clin Microbiol Infect Dis. 2012. PMID: 21822563
-
[Incidence and diagnosis of invasive pneumococcal disease].Ugeskr Laeger. 2004 May 24;166(22):2133-7. Ugeskr Laeger. 2004. PMID: 15222163 Review. Danish. No abstract available.
-
Medical microbiology: laboratory diagnosis of invasive pneumococcal disease.Clin Infect Dis. 2008 Mar 15;46(6):926-32. doi: 10.1086/528798. Clin Infect Dis. 2008. PMID: 18260752 Review.
Cited by
-
Anomalous results using countercurrent immunoelectrophoresis for the detection of pneumococcal antigen in Bactec blood culture media.J Clin Pathol. 1984 May;37(5):571-2. doi: 10.1136/jcp.37.5.571. J Clin Pathol. 1984. PMID: 6725602 Free PMC article.
-
Methods for optimal recovery of Malassezia furfur from blood culture.J Clin Microbiol. 1986 Nov;24(5):696-700. doi: 10.1128/jcm.24.5.696-700.1986. J Clin Microbiol. 1986. PMID: 3771759 Free PMC article.
-
Biomarker-guided antibiotic stewardship in suspected ventilator-associated pneumonia (VAPrapid2): a randomised controlled trial and process evaluation.Lancet Respir Med. 2020 Feb;8(2):182-191. doi: 10.1016/S2213-2600(19)30367-4. Epub 2019 Dec 3. Lancet Respir Med. 2020. PMID: 31810865 Free PMC article. Clinical Trial.
-
False-negative culture results with fungal isolates from peritoneal dialysis fluid.J Clin Microbiol. 2006 Mar;44(3):1206. doi: 10.1128/JCM.44.3.1206.2006. J Clin Microbiol. 2006. PMID: 16517934 Free PMC article. No abstract available.
-
Molecular Detection of Pathogens in Negative Blood Cultures in the Lao People's Democratic Republic.Am J Trop Med Hyg. 2021 Mar 1;104(4):1582-1585. doi: 10.4269/ajtmh.20-1348. Am J Trop Med Hyg. 2021. PMID: 33646978 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical