Precordial contrast echocardiographic detection of patent ductus arteriosus in small preterm infants
- PMID: 7122259
- DOI: 10.1007/BF02426972
Precordial contrast echocardiographic detection of patent ductus arteriosus in small preterm infants
Abstract
Clinical detection of patent ductus arteriosus (PDA) remains an important and challenging problem in the small preterm infant with respiratory distress. In this study, PDA was diagnosed in 28 small preterms using an improved contrast echocardiographic method. In these infants, the injection of saline into the aorta generated echoes which were imaged at the pulmonary valve. This was accomplished using a conventional M-mode ultrasound transducer applied at the usual precordial position. Contrast echo studies were compared with the degree of ductal patency shown by single film aortography. Ductal patency was detected by contrast echo in 29 of 31 instances of aortographically proven PDA. Indirect echo indices commonly used for detection of PDA (cardiac chamber enlargement) may be limited since factors other than left-to-right shunt can cause cardiac enlargement in distressed small preterms. This direct contrast echo technique is an easily performed, sensitive, qualitative method for confirmation of the diagnosis of PDA in small preterm infants.
Similar articles
-
Contrast echocardiographic assessment of the neonatal ductus arteriosus.Arch Dis Child. 1986 May;61(5):484-8. doi: 10.1136/adc.61.5.484. Arch Dis Child. 1986. PMID: 3717995 Free PMC article.
-
Unusual ultrasound finding of patent ductus arteriosus in a preterm infant.Pediatr Cardiol. 1988;9(1):37-9. doi: 10.1007/BF02279882. Pediatr Cardiol. 1988. PMID: 3347590
-
Electrical Cardiometry to Monitor Cardiac Output in Preterm Infants with Patent Ductus Arteriosus: A Comparison with Echocardiography.Neonatology. 2017;112(3):231-237. doi: 10.1159/000475774. Epub 2017 Jul 14. Neonatology. 2017. PMID: 28704819
-
Patent ductus arteriosus in the preterm infant.Neonatal Netw. 1996 Mar;15(2):19-26. Neonatal Netw. 1996. PMID: 8700090 Review.
-
Application of NPE in the assessment of a patent ductus arteriosus.Pediatr Res. 2018 Jul;84(Suppl 1):46-56. doi: 10.1038/s41390-018-0077-x. Pediatr Res. 2018. PMID: 30072803 Free PMC article. Review.
Cited by
-
Contrast echocardiographic assessment of the neonatal ductus arteriosus.Arch Dis Child. 1986 May;61(5):484-8. doi: 10.1136/adc.61.5.484. Arch Dis Child. 1986. PMID: 3717995 Free PMC article.
-
Effects of prolonged versus acute indomethacin therapy in very low birth-weight infants with patent ductus arteriosus.Eur J Pediatr. 1988 Jun;147(5):481-4. doi: 10.1007/BF00441971. Eur J Pediatr. 1988. PMID: 3409924 Clinical Trial.
-
Pulse wave patterns in patent ductus arteriosus.Arch Dis Child. 1983 Sep;58(9):682-5. doi: 10.1136/adc.58.9.682. Arch Dis Child. 1983. PMID: 6625629 Free PMC article.
-
The silent ductus: its precursors and its aftermath.Pediatr Cardiol. 1986;7(3):121-7. doi: 10.1007/BF02424985. Pediatr Cardiol. 1986. PMID: 3468491 Clinical Trial.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical