Aseptic loosening of cement-anchored total hip replacements
- PMID: 7125870
- DOI: 10.1007/BF00381538
Aseptic loosening of cement-anchored total hip replacements
Abstract
The special conditions contributing to the loosening of 61 hip prostheses were studied and compared with 325 clinical and roentgenologically intact total hip replacements. The loosening rate rose sharply after the 6th postoperative year. One third of the artificial joints examined showed signs of loosening after the 9th year. The average loosening rate was 15.8% after 5.8 years. The condition of the bony bed apparently plays an important role, both qualitatively and quantitatively, in the success of the implant. The operative procedure is of equal importance. Deep fraising of the acetabulum, removal of insufficient amounts of cancellous bone from the proximal femur and inadequate embedding of the prosthesis stem, implantation of the stem in varus, and the use of long-neck femoral head prostheses are all factors which increase the risk of loosening. Ultimately, it is the sum of these loosening factors including the biological reaction of the tissue to the biomechanical and biochemically active foreign body which, depending on the period of influence, leads to prosthesis loosening. It is imperative that the patient's lifestyle be adjusted accordingly since external weight-bearing stress also affects durability of the prosthesis.
Similar articles
-
Conus hip prosthesis.Acta Chir Orthop Traumatol Cech. 2001;68(4):213-21. Acta Chir Orthop Traumatol Cech. 2001. PMID: 11706545
-
Biomechanical factors in loosening of the Stanmore hip.Acta Orthop Scand. 1985 Feb;56(1):21-4. doi: 10.3109/17453678508992972. Acta Orthop Scand. 1985. PMID: 3984699
-
[The significance of wear and material fatigue in loosening of hip prostheses].Orthopade. 1989 Sep;18(5):350-69. Orthopade. 1989. PMID: 2682455 German.
-
[Etiology, diagnosis and therapy of aseptic hip prosthesis loosening--a status assessment].Z Orthop Ihre Grenzgeb. 1997 Jul-Aug;135(4):270-80. doi: 10.1055/s-2008-1039388. Z Orthop Ihre Grenzgeb. 1997. PMID: 9381761 Review. German.
-
[Whether bone quality matters or not in durability of total hip arthroplasty? Bone quality matters in durability of total hip arthroplasty].Clin Calcium. 2011 May;21(5):746-50. Clin Calcium. 2011. PMID: 21532126 Review. Japanese.
Cited by
-
Morphological investigations of a porous aluminum oxide ceramic and the consequences for clinical application.Arch Orthop Trauma Surg (1978). 1987;106(6):385-9. doi: 10.1007/BF00456875. Arch Orthop Trauma Surg (1978). 1987. PMID: 3435239
-
Uncoated polyethylene RM acetabular component versus Müller cemented acetabular component. A 4- to 8-year follow-up study.Arch Orthop Trauma Surg. 1991;110(4):195-9. doi: 10.1007/BF00571058. Arch Orthop Trauma Surg. 1991. PMID: 1892714
-
Rare fracture of a total hip replacement.Arch Orthop Trauma Surg (1978). 1983;101(3):183-5. doi: 10.1007/BF00436769. Arch Orthop Trauma Surg (1978). 1983. PMID: 6870507
-
Computer-aided manufacture of individual endoprostheses. Preliminary communication.Arch Orthop Trauma Surg (1978). 1983;102(1):31-5. doi: 10.1007/BF00443036. Arch Orthop Trauma Surg (1978). 1983. PMID: 6639310
-
Aseptic loosening of straight- and curved-stem Müller femoral prostheses.Arch Orthop Trauma Surg. 1991;110(4):190-4. doi: 10.1007/BF00571057. Arch Orthop Trauma Surg. 1991. PMID: 1892713
References
MeSH terms
LinkOut - more resources
Medical