Bone blood flow in the femora of anesthetized and conscious dogs in a chronic preparation, using the radioactive tracer microsphere method
- PMID: 7127959
Bone blood flow in the femora of anesthetized and conscious dogs in a chronic preparation, using the radioactive tracer microsphere method
Abstract
The radioactive tracer microsphere method is applicable to the study of the hemodynamics of bone. As observed previously by others, areas of predominantly cancellous bone produce higher blood flow measurements than do areas of predominantly cortical bone. Bone containing fatty marrow has lower blood flow rates than does bone containing hematopoietic marrow. Blood flow to the femoral neck was the greatest measured (26.74 +/- 1.95 ml/min/100 gm), while the diaphyseal region was the area with the lowest flow (4.67 +/- 0.46 ml/min/100 gm). There was no significant difference between consecutive measurements using up to five differently labeled radioactive microspheres. This enabled observations of the effects of an experimental procedure on bone blood flow in the same animal. Additionally, there was no statistically significant differences between regional blood flows measured 40 days apart in the same animal. Bone blood flow measurements were slightly lower in anesthetized than in conscious dogs. The RTM method is the one most suitable for the estimation of bone blood flow under either acute or chronic conditions.
Similar articles
-
Experimental study of measurement of regional bone blood flow in the adult mongrel dog using radioactive microspheres.Clin Orthop Relat Res. 1979 Jan-Feb;(138):263-70. Clin Orthop Relat Res. 1979. PMID: 445909
-
Measurement of bone blood flow using the hydrogen washout technique-part II: Validation by comparison to microsphere entrapment.J Orthop Res. 2008 Jun;26(6):746-52. doi: 10.1002/jor.20561. J Orthop Res. 2008. PMID: 18203184
-
Canine bone blood flow estimated with microspheres.J Orthop Res. 1989;7(1):61-7. doi: 10.1002/jor.1100070109. J Orthop Res. 1989. PMID: 2908913
-
Developments in non-radioactive microsphere techniques for blood flow measurement.Cardiovasc Res. 1994 Oct;28(10):1467-75. doi: 10.1093/cvr/28.10.1467. Cardiovasc Res. 1994. PMID: 8001033 Review.
-
Blood flow distributions by microsphere deposition methods.Cardiovasc Res. 2000 Jan 1;45(1):13-21. doi: 10.1016/s0008-6363(99)00252-7. Cardiovasc Res. 2000. PMID: 10728307 Free PMC article. Review.
Cited by
-
Evaluation of a laser Doppler flowmetry implantable fiber system for determination of threshold thickness for flow detection in bone.Calcif Tissue Int. 1994 Sep;55(3):216-22. doi: 10.1007/BF00425878. Calcif Tissue Int. 1994. PMID: 7987736
-
The apparent critical isotherm for cryoinsult-induced osteonecrotic lesions in emu femoral heads.J Biomech. 2008 Jul 19;41(10):2197-205. doi: 10.1016/j.jbiomech.2008.04.032. Epub 2008 Jun 17. J Biomech. 2008. PMID: 18561937 Free PMC article.
-
Evaluation of marrow perfusion in the femoral head by dynamic magnetic resonance imaging. Effect of venous occlusion in a dog model.Invest Radiol. 1992 Apr;27(4):275-81. doi: 10.1097/00004424-199204000-00002. Invest Radiol. 1992. PMID: 1601616 Free PMC article.
-
Assessment of the relationship between standard probe and implantable fiber measurements of cortical bone blood flow: a canine study.Calcif Tissue Int. 1996 Jul;59(1):64-9. doi: 10.1007/s002239900087. Calcif Tissue Int. 1996. PMID: 8661975
MeSH terms
Substances