Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: evaluation of the method
- PMID: 7134796
Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: evaluation of the method
Abstract
Interstitial fluid was collected from human subcutaneous tissue by implantation of multifilamentous nylon wicks on the side of thorax. The skin was anaesthetized by a small injection of lidocaine. Direct measurement of colloid osmotic pressure in a control group of 20 healthy volunteers gave a mean of 15.8 (SD 2.3) mmHg in wick fluid and 26.9 (SD 4.1) mmHg in serum samples. Standard deviation of the method for wick fluid samples was 1.2 mmHg. Significant blood contamination occurred in less than 20% of the wicks. Fluid content in wicks varied within narrow limits independent of its colloid osmotic pressure. The dynamics of wick fluid protein uptake was studied by uptake of 131I albumin from plasma, and by measurement of colloid osmotic pressure after 30, 60, 120 and 180 min of implantation. The results showed an initial rapid uptake from plasma of a major part of the wick fluid proteins within 30 min. After 120 min wick fluid colloid osmotic pressure reached the same level whether the wicks were 'primed' with serum proteins or not. Altogether these observations support the view that wick fluid reflects interstitial tissue fluid with respect to colloid osmotic pressure when the wicks are implanted for 60 min.
Similar articles
-
Colloid osmotic pressure of interstitial fluid in rat subcutis and skeletal muscle: comparison of various wick sampling techniques.Acta Physiol Scand. 1988 Jun;133(2):167-75. doi: 10.1111/j.1748-1716.1988.tb08396.x. Acta Physiol Scand. 1988. PMID: 3227913
-
Interstitial fluid colloid osmotic and hydrostatic pressures in subcutaneous tissue of patients with nephrotic syndrome.Scand J Clin Lab Invest. 1982 Apr;42(2):139-46. Scand J Clin Lab Invest. 1982. PMID: 7134798
-
Influence of body posture on transcapillary pressures in human subcutaneous tissue.Scand J Clin Lab Invest. 1982 Apr;42(2):131-8. Scand J Clin Lab Invest. 1982. PMID: 7134797
-
The problem of gaining access to interstitial fluid. An attempt to rationalize a wicked discussion on wicks.Lymphology. 1997 Sep;30(3):111-5. Lymphology. 1997. PMID: 9313202 Review. No abstract available.
-
A synthesis of interstitial fluid regulation and lymph formation.Fed Proc. 1976 Jun;35(8):1881-5. Fed Proc. 1976. PMID: 131712 Review.
Cited by
-
Interstitial fluid colloid osmotic pressure in healthy children.PLoS One. 2015 Apr 8;10(4):e0122779. doi: 10.1371/journal.pone.0122779. eCollection 2015. PLoS One. 2015. PMID: 25853713 Free PMC article. Clinical Trial.
-
Capillary leakage in post-cardiac arrest survivors during therapeutic hypothermia - a prospective, randomised study.Scand J Trauma Resusc Emerg Med. 2010 May 25;18:29. doi: 10.1186/1757-7241-18-29. Scand J Trauma Resusc Emerg Med. 2010. PMID: 20500876 Free PMC article. Clinical Trial.
-
Effect of topical anaesthetics on interstitial colloid osmotic pressure in human subcutaneous tissue sampled by wick technique.PLoS One. 2012;7(2):e31332. doi: 10.1371/journal.pone.0031332. Epub 2012 Feb 14. PLoS One. 2012. PMID: 22348071 Free PMC article. Clinical Trial.
-
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid.Nat Biomed Eng. 2023 Dec;7(12):1541-1555. doi: 10.1038/s41551-022-00998-9. Epub 2023 Jan 19. Nat Biomed Eng. 2023. PMID: 36658344 Review.
-
In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and a wick method.Klin Wochenschr. 1989 May 2;67(9):491-5. doi: 10.1007/BF01721675. Klin Wochenschr. 1989. PMID: 2733378