Bacteriological testing of a modified laminar flow microbiological safety cabinet
- PMID: 7149701
- DOI: 10.1007/BF00418290
Bacteriological testing of a modified laminar flow microbiological safety cabinet
Abstract
A modified microbiological safety cabinet which can be used as a class II and a class III safety cabinet has been bacteriologically tested. This cabinet makes use of a high-speed down-flow air curtain in the front opening to minimize the amount of air escaping over the arms of the operator. By using artificial aerosols and a dummy or a test person placing his arms into the working opening of the cabinet, a transfer from the inside to the environment was detected only when the highest concentration of the test aerosol was used. Since the number of bacteria detected was very low, this is considered to be acceptable. When the cabinet was used as a class III type, with a glove panel mounted in the front opening, leakage from the environment occurred. This could be completely prevented by fixing tape over the hinge of the front panel. The conclusion is drawn that this type of biohazard hood can be safely used as a class II and a class III microbiological safety cabinet, provided the construction of the hinge of the front panel will be adapted to prevent transfer from the environment to the working area.
Similar articles
-
Modified laminar flow biological safety cabinet.Appl Microbiol. 1974 Oct;28(4):647-50. doi: 10.1128/am.28.4.647-650.1974. Appl Microbiol. 1974. PMID: 4420479 Free PMC article.
-
Containment of microbial aerosols in a microbiological safety cabinet.Appl Microbiol. 1968 Aug;16(8):1225-9. doi: 10.1128/am.16.8.1225-1229.1968. Appl Microbiol. 1968. PMID: 4877500 Free PMC article.
-
Evaluation of laminar flow microbiological safety cabinets.Appl Microbiol. 1968 Oct;16(10):1478-82. doi: 10.1128/am.16.10.1478-1482.1968. Appl Microbiol. 1968. PMID: 4971719 Free PMC article.
-
Biological safety cabinetry.Clin Microbiol Rev. 1991 Apr;4(2):207-41. doi: 10.1128/CMR.4.2.207. Clin Microbiol Rev. 1991. PMID: 2070345 Free PMC article. Review.
-
Microbiological safety cabinets: selection, installation, testing and use.Br J Biomed Sci. 2000;57(4):330-7. Br J Biomed Sci. 2000. PMID: 11204866 Review.
Cited by
-
Evidence-based biosafety: a review of the principles and effectiveness of microbiological containment measures.Clin Microbiol Rev. 2008 Jul;21(3):403-25. doi: 10.1128/CMR.00014-08. Clin Microbiol Rev. 2008. PMID: 18625678 Free PMC article. Review.
References
MeSH terms
LinkOut - more resources
Medical