Continuous monitoring of mixed venous oxygen saturation in critically ill patients
- PMID: 7200741
Continuous monitoring of mixed venous oxygen saturation in critically ill patients
Abstract
A new pulmonary artery balloon flow-directed catheter combines a fiberoptic photometric system for continuous display of mixed venous blood oxygen saturation (SvO2) with the capacity for hemodynamic measurements including thermodilution cardiac output estimation. This oximetry system was studied to determine its accuracy, reliability, and usefulness in the surgical intensive care unit (ICU). Twenty-two catheters were tested, but only 17 were successfully placed in 16 patients. There were technical problems associated with 10 catheters and on six occasions these necessitated the use of another catheter. The catheter values for SvO2 were closely related (r = 0.9516) to those obtained from a laboratory Co-oximeter. Continuous monitoring of SvO2 is accurate and valuable as a warning system for deterioration in cardiopulmonary function and as an indicator of the effects of various therapeutic maneuvers in critically ill patients.
Similar articles
-
Clinical implications of intraoperative continuous mixed venous oxygen saturation monitoring.AANA J. 1989 Feb;57(1):45-52. AANA J. 1989. PMID: 2929243
-
Clinical evaluation of a new fiberoptic catheter oximeter during cardiac surgery.Anesth Analg. 1982 Aug;61(8):676-9. Anesth Analg. 1982. PMID: 6979954
-
A comparison between a conventional and a fiberoptic flow-directed thermal dilution pulmonary artery catheter in critically ill patients.Arch Intern Med. 1989 Jan;149(1):83-5. Arch Intern Med. 1989. PMID: 2912419 Clinical Trial.
-
Venous oximetry.Curr Opin Crit Care. 2006 Jun;12(3):263-8. doi: 10.1097/01.ccx.0000224872.09077.dc. Curr Opin Crit Care. 2006. PMID: 16672787 Review.
-
[The role of mixed venous oxygen saturation in perioperative monitoring and therapy. A critical stock taking].Anasthesiol Intensivmed Notfallmed Schmerzther. 1993 Aug;28(5):269-78. doi: 10.1055/s-2007-998924. Anasthesiol Intensivmed Notfallmed Schmerzther. 1993. PMID: 8373972 Review. German.
Cited by
-
Continuous mixed venous oxygen saturation measurement: a significant advance in hemodynamic monitoring?J Clin Monit. 1985 Oct;1(4):245-58. doi: 10.1007/BF02832818. J Clin Monit. 1985. PMID: 3938481 Review.
-
Central venous oxygenation: when physiology explains apparent discrepancies.Crit Care. 2014 Nov 10;18(6):579. doi: 10.1186/s13054-014-0579-9. Crit Care. 2014. PMID: 25407250 Free PMC article. Review.
-
Effect of heparinization of catheters on pulmonary artery oximetry.J Clin Monit. 1988 Jul;4(3):204-9. doi: 10.1007/BF01621817. J Clin Monit. 1988. PMID: 3210068
-
Continuous monitoring of mixed venous oxygen saturation in septic shock.J Clin Monit. 1986 Oct;2(4):237-45. doi: 10.1007/BF02851172. J Clin Monit. 1986. PMID: 3097269
-
CT contrast predicts pancreatic cancer treatment response to verteporfin-based photodynamic therapy.Phys Med Biol. 2014 Apr 21;59(8):1911-21. doi: 10.1088/0031-9155/59/8/1911. Epub 2014 Mar 20. Phys Med Biol. 2014. PMID: 24651456 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical