Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1981 Feb;88(2):268-73.
doi: 10.1083/jcb.88.2.268.

Application of scanning electron microscopy to x-ray analysis of frozen-hydrated sections. II. Analysis of standard solutions and artificial electrolyte gradients

Application of scanning electron microscopy to x-ray analysis of frozen-hydrated sections. II. Analysis of standard solutions and artificial electrolyte gradients

A J Saubermann et al. J Cell Biol. 1981 Feb.

Abstract

New specimen handling and analytic techniques for the application of x-ray microanalysis to studies of cell and organ biology have been recently described (Saubermann et al., 1981, J. Cell Biol. 88:257-267). Based on these techniques, absolute quantitative standardization has been established through x-ray analysis of frozen-hydrated and then dried sections of independently measured standard solutions of elements. These experiments demonstrate that the specific techniques employed have a probable error of less than 10%. Artificial electrolyte gradients established in gelatin were subjected to analysis to determine whether there was elemental displacement under non-membrane-limited conditions at the temperatures employed for sectioning (-30 degrees to -40 degrees C). No significant difference was observed between such gradients in serial sections cut at -30 degrees and -80 degrees C. Similarly, no additional ice-crystal-damage artifact was found in sections cut at -30 degrees C when compared with sections cut at -80 degrees C. Thus, in terms of ice-crystal size, gradient maintenance, and compartmental differentiation, cryosectioning at -30 degrees to -40 degrees C was not associated with redistribution incompatible with 1- to 2-micrometers spatial resolution, and absolute measurements of elemental concentration were practical within regions of this size.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Cell Biol. 1971 Dec;51(3):772-804 - PubMed
    1. Rev Sci Instrum. 1974 Feb;45(2):252-5 - PubMed
    1. J Microsc. 1974 Jan;100(1):49-74 - PubMed
    1. J Microsc. 1975 Nov;105(2):155-91 - PubMed
    1. J Microsc. 1976 Apr;106(3):291-302 - PubMed

Publication types