Measurement of portal-systemic shunting in the rat by using gamma-labeled microspheres
- PMID: 7235023
- DOI: 10.1152/ajpgi.1981.240.5.G371
Measurement of portal-systemic shunting in the rat by using gamma-labeled microspheres
Abstract
A method for determining the extent of portal-systemic shunting (PSS) is described and evaluated in lightly anesthetized (ketamine) rats. This method relies on the intrasplenic injection of 15-micrometers gamma-labeled spheres and the subsequent measurement of liver and lung radioactivities. After the splenic injection of the microspheres, a fraction of microspheres shunting the hepatic sinusoidal bed will be entrapped in the lungs. Thus, the ratio, lung/(lung + liver) radioactivities, will indicate the degree of PSS. The percent of PSS was determined in normal (n = 13; 1.2 +/- 0.3%), in cirrhotic (n = 9; 15.0 +/- 4.5%; P less than 0.01), and in portal vein-ligated animals (n = 14; 95.0 +/- 0.9%; P less than 0.001 for normal and cirrhotic). In addition, PSS was sequentially quantitated (n = 3) before (3.0%) and after (89%) partial portal vein ligation. The variability of PSS found in cirrhotic rats (0.7-41.0%) is in agreement with the reported data for PSS in patients. This technique, which is simple, rapid, and reproducible, allows the quantitation of PSS in small laboratory animals.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources