[Extracapsular cataract extraction combined with the implantation of an intraocular lens (author's transl)]
- PMID: 7241937
- DOI: 10.1055/s-2008-1057203
[Extracapsular cataract extraction combined with the implantation of an intraocular lens (author's transl)]
Abstract
Between 1973 and 1980 349 intraocular lenses were implanted after intracapsular and 470 after extracapsular cataract operation. The results and complications are evaluated: following intracapsular lens extraction a 4-loop Binkhorst lens (iris clip lens) was inserted in all cases. Following extracapsular cataract operation a 2-loop Binkhorst lens (iridocapsular lens) was implanted in 194, a 4-loop lens in 276 cases. The two complications occurring most frequently were an Irvine-Gass syndrome in 10% following intracapsular, and a disturbing secondary cataract necessitating a discision in 19% after extracapsular lens extraction. A dislocation-decentration of the pseudophakos was observed in some cases after extracapsular cataract operation. It is therefore recommended that the extracapsular be preferred to the intracapsular cataract extraction, that a 4-loop lens be implanted, secured by a transiridectomy suture, but that the haptic part of the intraocular lens should not be inserted in the capsular bag. It is of paramount importance, especially in young pseudophakic patients, to prescribe carefully an additional optical correction, preferably progressive glasses.
Similar articles
-
[A review of 400 intraocular lens implants (author's transl)].Klin Monbl Augenheilkd. 1979 Jun;174(6):895-7. Klin Monbl Augenheilkd. 1979. PMID: 480843 German.
-
[Anterior chamber lens implantation with intracapsular cataract extraction (author's transl)].Klin Monbl Augenheilkd. 1981 Apr;178(4):278-80. doi: 10.1055/s-2008-1057202. Klin Monbl Augenheilkd. 1981. PMID: 7241936 German.
-
[Treatment of cystoid macular edema after intracapsular cataract extraction and implantation of the Binkhorst 4-loop lens].Wien Klin Wochenschr. 1985 Aug 9;97(15):625-7. Wien Klin Wochenschr. 1985. PMID: 4049887 German.
-
[Artificial crystalline lenses and Fuchs' syndrome].J Fr Ophtalmol. 1988;11(10):651-6. J Fr Ophtalmol. 1988. PMID: 3072364 Review. French.
-
[Comparative evaluation of intracapsular cataract extraction, extracapsular cataract extraction and phacoemulsification].Fortschr Ophthalmol. 1990;87 Suppl:S14-21. Fortschr Ophthalmol. 1990. PMID: 2083893 Review. German.