Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1981 May;11(3):228-36.
doi: 10.1007/BF01967619.

Fluorometric determination of peripheral tissue histamine levels using Bio-Rex 70

Fluorometric determination of peripheral tissue histamine levels using Bio-Rex 70

S J Lewis et al. Agents Actions. 1981 May.

Abstract

Bio-Rex 70, a weak cation exchange resin, has been incorporated into a column chromatographic extraction procedure for the determination of peripheral tissue levels of histamine. The extracted histamine is quantified fluorometrically after condensation with o-phthaldialdehyde (OPT). The sensitivity of the procedure allows for the chromatographic extraction, using Bio-Rex 70, of 10 ng histamine to give fluorescence twice that of the blank. Because this extraction procedure does not separate histamine from spermidine it cannot be applied in determining levels of brain histamine. However, because spermidine in concentrations of up to 400 times that of histamine does not interfere with OPT-histamine fluorescence, the histamine levels of all peripheral tissues (including nerves) and fluids may be confidently examined. The relative simplicity of the procedure allows for the determination of 30 tissue samples within a working day. The method has been applied to determine peripheral tissue levels of histamine in naïve Wistar rats and the effects of compound 48/80 on these levels in several selected tissues have been investigated. Compound 48/80 decreased the levels of histamine in the heart, kidney and ileum, whereas these levels were initially elevated in the liver and lung without subsequent depletion. Since the reliability of existing histamine extraction procedures is questionable under certain conditions, it is suggested that the use of Bio-Rex 70 is a valuable addition in evaluating the possible physiological role(s) of tissue histamine.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Pharmacol Exp Ther. 1959 Nov;127:182-6 - PubMed
    1. Anesthesiology. 1946 May;7:260-2 - PubMed
    1. Agents Actions. 1974 Dec;4(5):324-35 - PubMed
    1. Circ Res. 1967 Dec;21(6):833-47 - PubMed
    1. Anal Biochem. 1973 Aug;54(2):353-61 - PubMed