Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1981 Nov;98(5):691-6.

A rapid method for the determination of ultrafilterable calcium in serum

  • PMID: 7299241
Comparative Study

A rapid method for the determination of ultrafilterable calcium in serum

J Wortsman et al. J Lab Clin Med. 1981 Nov.

Abstract

Alterations of calcium homeostasis may be expressed as hypercalcemia, hypocalcemia, and normocalcemia with abnormal distribution of serum calcium fractions. The accurate diagnosis of disorders of calcium homeostasis requires the direct determination of free (ionized) serum calcium. The major problem in the direct measurement of ionized calcium with a calcium-sensitive electrode is the dependence on an anaerobic environment. We evaluated the determination of ultrafilterable calcium in serum as an index of free calcium unbound concentration. Ultrafilterable calcium measured in normal subjects by membrane binding analysis was (mean +/- S.E.M.) 4.8 +/ 0.14 mg/dl. The intra-assay coefficient of variation was 2.9% for ultrafilterable calcium and 3.0% for the calculated fraction bound to proteins. Storage at 0 degrees C had minimal effects: the interassay coefficient of variation was 5.1% for ultrafilterable calcium and 8.5% for the protein-bound fraction. The same determinations in a serum pool standard showed an interassay coefficient of variation of 4.8% and 4.2%, respectively. Freezing and thawing for up to three times did not affect ultrafilterable calcium concentration. In 56 subjects who were normocalcemic, hypercalcemic, or hypocalcemic, simultaneous determination of ionized calcium (by a calcium electrode) and ultrafilterable calcium showed a correlation coefficient of 0.91 (p less than 0.001). These results show that membrane-binding analysis by ultrafiltration is a valid method, suitable for the routine determination of unbound (free) calcium in normal subjects and in patients with disorders with calcium homeostasis.

PubMed Disclaimer

Publication types

LinkOut - more resources