Carotid artery velocity patterns in normal and stenotic vessels
- PMID: 7355433
- DOI: 10.1161/01.str.11.1.67
Carotid artery velocity patterns in normal and stenotic vessels
Abstract
Duplex scanning provides real time B-mode images of the carotid bifurcation vessels along with a single gate pulsed Doppler flow velocity detector. By using the B-mode output of the duplex system to measure the Doppler angle and spectrum analysis to measure the frequency content of the Doppler signal, instantaneous flow velocity can be calculated. Mean velocity at peak systole was calculated retrospectively in 68 common (CCA) and internal (ICA) carotid arteries of 39 patients who had undergone prior angiography and prospectively in 30 arteries of 15 healthy young controls. The ratio of mean peak ICA velocity to mean peak CCA velocity at systole (VICA/VCCA) was below 0.8 in all 36 normal arteries and above 1.5 in all 21 high-grade stenoses of 60% or greater diameter reduction. Sixty-one percent of 41 vessels with less than 10 to 55% diameter reduction had a velocity ratio between 0.8 and 1.5. Only 10% of all ICA's with any stenotic lesion were incorrectly classified as normal. VICA/VCCA appears to be an accurate indicator of the degree of ICA stenosis.
Similar articles
-
Ability to use duplex US to quantify internal carotid arterial stenoses: fact or fiction?Radiology. 2000 Jan;214(1):247-52. doi: 10.1148/radiology.214.1.r00ja27247. Radiology. 2000. PMID: 10644132
-
Correlation of duplex scanning and two plane angiography in patients with symptomatic carotid stenosis.Acta Chir Belg. 1988 May-Jun;88(3):159-61. Acta Chir Belg. 1988. PMID: 3051820
-
Reproducibility of carotid artery Doppler frequency measurements.Stroke. 1985 Nov-Dec;16(6):973-6. doi: 10.1161/01.str.16.6.973. Stroke. 1985. PMID: 3911509
-
Carotid artery duplex scanning.J Clin Ultrasound. 1987 Nov-Dec;15(9):635-44. doi: 10.1002/jcu.1870150906. J Clin Ultrasound. 1987. PMID: 3119668 Review.
-
Ultrasound in the study of atherosclerosis.Ultrasound Med Biol. 1986 Jun;12(6):453-64. doi: 10.1016/0301-5629(86)90217-6. Ultrasound Med Biol. 1986. PMID: 3523920 Review.
Cited by
-
Blood flow velocity waveform in the common carotid artery and its analysis in elderly subjects.Clin Auton Res. 1992 Jun;2(3):197-200. doi: 10.1007/BF01818962. Clin Auton Res. 1992. PMID: 1498566
-
Effects of antihypertensive agents on blood velocity: implications for atherogenesis.Can Med Assoc J. 1982 Oct 15;127(8):721-4. Can Med Assoc J. 1982. PMID: 7139486 Free PMC article.
-
Changes of time-attenuation curve blood flow parameters in patients with and without carotid stenosis.AJNR Am J Neuroradiol. 2015 Jun;36(6):1176-81. doi: 10.3174/ajnr.A4239. Epub 2015 Feb 26. AJNR Am J Neuroradiol. 2015. PMID: 25721077 Free PMC article.
-
Duplex carotid ultrasound.Neuroradiology. 1986;28(5-6):608-17. doi: 10.1007/BF00344109. Neuroradiology. 1986. PMID: 2948133
-
Reproducibility of Doppler blood flow velocity waveform measurements: study on variability within and between day and during haemodynamic intervention in normal subjects.Eur J Clin Pharmacol. 1991;41(2):125-9. doi: 10.1007/BF00265904. Eur J Clin Pharmacol. 1991. PMID: 1743244
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous