Renal clearance and extraction parameters of ortho-iodohippurate (I-123) compared with OIH(I-131) and PAH
- PMID: 7356755
Renal clearance and extraction parameters of ortho-iodohippurate (I-123) compared with OIH(I-131) and PAH
Abstract
o-[131I] iodohippurate [OIH(I-131)] has been used for many years in the estimation of effective renal plasma flow. This compound suffers from low photon yield and poor images when the quantity used is limited to stay within a reasonable radiation dose. To test the validity of substituting I-123 for I-131, a series of experiments was performed in a surgically prepared dog model. The extraction ratios and clearance values OIH(I-123) prepared from radionuclidically pure I-123 were compared with those of commercial OIH(I-131) and PAH. The extraction ratios for OIH(I-123) and OIH(I-131) were 0.65 and 0.67, representing 0.86 and 0.88 that of PAH, respectively. The clearance values (cc/min/kg) for the I123 and I-123) can be used to estimate effective renal plasma flow; moreover, because of the high yield within an acceptable radiation dose range, images of good quality can be produced.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources