Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique
- PMID: 7358417
- DOI: 10.1109/TBME.1980.326616
Indirect measurement of instantaneous arterial blood pressure in the human finger by the vascular unloading technique
Similar articles
-
[Noninvasive measurement of instantaneous arterial blood pressure using vascular unloading technique (author's transl)].Iyodenshi To Seitai Kogaku. 1980 Sep;18(5):352-9. Iyodenshi To Seitai Kogaku. 1980. PMID: 7241846 Japanese. No abstract available.
-
[Vascular-volume compensation method for noninvasive measurement of instantaneous arterial blood pressure: its usefulness in psychological research].Shinrigaku Kenkyu. 1983 Aug;54(3):204-7. Shinrigaku Kenkyu. 1983. PMID: 6672377 Japanese.
-
[D-SGP Duo--a new plethysmography for acral, arterial and venous blood pressure measurement].Vasa Suppl. 1991;33:308-9. Vasa Suppl. 1991. PMID: 1788729 German.
-
[Noninvasive, continuous measurement of finger artery pressure with the servo-plethysmo-manometer Finapres].Herz. 1989 Aug;14(4):251-9. Herz. 1989. PMID: 2676814 Review. German.
-
[Indirect measurement of arterial blood pressure by plethysmography].Nihon Rinsho. 1997 Mar;55 Suppl 1:519-22. Nihon Rinsho. 1997. PMID: 9097665 Review. Japanese. No abstract available.
Cited by
-
Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries.Med Biol Eng Comput. 1989 Sep;27(5):477-83. doi: 10.1007/BF02441465. Med Biol Eng Comput. 1989. PMID: 2622228
-
Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration.Med Biol Eng Comput. 2000 Sep;38(5):569-74. doi: 10.1007/BF02345755. Med Biol Eng Comput. 2000. PMID: 11094816
-
Ambulatory monitoring of indirect beat-to-beat arterial pressure in human fingers by a volume-compensation method.Med Biol Eng Comput. 1991 Jan;29(1):55-62. doi: 10.1007/BF02446296. Med Biol Eng Comput. 1991. PMID: 2016921
-
Vibration technique for indirect measurement of diastolic arterial pressure in human fingers.Med Biol Eng Comput. 1989 Mar;27(2):130-6. doi: 10.1007/BF02446221. Med Biol Eng Comput. 1989. PMID: 2601431
-
Noninvasive automatic monitoring of instantaneous arterial blood pressure using the vascular unloading technique.Med Biol Eng Comput. 1983 Sep;21(5):557-65. doi: 10.1007/BF02442380. Med Biol Eng Comput. 1983. PMID: 6633005 No abstract available.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources