The use of principal components in the quantitative analysis of gamma camera dynamic studies
- PMID: 7384214
- DOI: 10.1088/0031-9155/25/2/008
The use of principal components in the quantitative analysis of gamma camera dynamic studies
Abstract
The reduction of the enormous quantity of data in a radionuclide dynamic study to a few diagnostic parameters presents a problem. Conventional methods of data reduction using regions-of-interest or functional images have several defects which potentially limit their usefulness. Using a principal components analysis of the elemental curves representing the change of activity with time in each pixel, followed by a further factor analysis, it is possible to extract the fundamental functional changes of activity which underly the observed variation of activity. An example of this analysis on a dynamic brain scan suggests that the three fundamental phases of activity represent activity in the arterial system, the venous system and diffusion of tracer into the tissues.
Similar articles
-
Camera-computer systems for rapid dynamic imaging studies.Semin Nucl Med. 1977 Oct;7(4):323-36. doi: 10.1016/s0001-2998(77)80041-x. Semin Nucl Med. 1977. PMID: 335515
-
Digital computer processing of brain scans using principal components.Phys Med Biol. 1976 Sep;21(5):792-803. doi: 10.1088/0031-9155/21/5/008. Phys Med Biol. 1976. PMID: 967928
-
[Deadtime correction in quantitative dynamic studies with the Anger camera and computer].Radiol Med. 1978 Oct;64(10):1175-7. Radiol Med. 1978. PMID: 734193 Italian. No abstract available.
-
[New medical imaging based on electron tracking Compton camera (ETCC)].Igaku Butsuri. 2012;32(3):111-8. Igaku Butsuri. 2012. PMID: 24592680 Review. Japanese.
-
[Radioisotopes in cardiology. Introduction].Arch Mal Coeur Vaiss. 1980 Jan;73(1):4-12. Arch Mal Coeur Vaiss. 1980. PMID: 6770781 Review. French.
Cited by
-
Diagnosis of malignancy in thyroid nodules by factor analysis of spectral and dynamic structures: a simultaneous dual-isotope dynamic study with thallium-201 and iodine-131.Eur J Nucl Med. 1992;19(7):517-21. doi: 10.1007/BF00185858. Eur J Nucl Med. 1992. PMID: 1644108
-
Image-derived input function with factor analysis and a-priori information.Nucl Med Commun. 2015 Feb;36(2):187-93. doi: 10.1097/MNM.0000000000000231. Nucl Med Commun. 2015. PMID: 25321159 Free PMC article.
-
FAST ANALYTICAL RECONSTRUCTION OF GATED CARDIAC SPECT WITH NON-UNIFORM ATTENUATION COMPENSATION.Int J Image Graph. 2007 Jan;7(1):87-104. doi: 10.1142/S0219467807002556. Int J Image Graph. 2007. PMID: 18509522 Free PMC article.
-
Objective models of compressed breast shapes undergoing mammography.Med Phys. 2013 Mar;40(3):031902. doi: 10.1118/1.4789579. Med Phys. 2013. PMID: 23464317 Free PMC article.
-
Parametric image of myocardial blood flow generated from dynamic H2(15)O PET using factor analysis and cluster analysis.Med Biol Eng Comput. 2005 Sep;43(5):678-85. doi: 10.1007/BF02351043. Med Biol Eng Comput. 2005. PMID: 16411642
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical