Tear film physiology
- PMID: 7386586
- DOI: 10.1097/00006324-198004000-00008
Tear film physiology
Abstract
Current understanding of tear film physiology is based on the anatomy of each of the three layers, as well as on the changes that occur with blinking and on the physicochemical properties of the tear fluid. Abnormalities in tear film may be due to deficiency of aqueous tears or mucin, changes in the lipid layer, inadequate blinking, or epithelial pathology. Patients who have marginal deficiencies tend to be symptom-free but will develop symptoms promptly if contact lenses are fitted.
Similar articles
-
Tear film physiology.Int Ophthalmol Clin. 1987 Spring;27(1):2-6. doi: 10.1097/00004397-198702710-00002. Int Ophthalmol Clin. 1987. PMID: 3818196 No abstract available.
-
Physical chemistry of the normal and disordered tear film.Trans Ophthalmol Soc U K (1962). 1985;104 ( Pt 4):374-80. Trans Ophthalmol Soc U K (1962). 1985. PMID: 3862270
-
Surface phenomena of the tear film.Am J Ophthalmol. 1969 Jan;67(1):56-64. doi: 10.1016/0002-9394(69)90008-7. Am J Ophthalmol. 1969. PMID: 4178152 No abstract available.
-
[The lipid layer of the lacrimal tear film: physiology and pathology].J Fr Ophtalmol. 2001 Jun;24(6):643-58. J Fr Ophtalmol. 2001. PMID: 11460063 Review. French.
-
Architecture of the lid-cornea juncture.CLAO J. 1992 Jul;18(3):187-92. CLAO J. 1992. PMID: 1499127 Review.
Cited by
-
Congenital deficiency of meibomian glands.Br J Ophthalmol. 1987 Apr;71(4):312-4. doi: 10.1136/bjo.71.4.312. Br J Ophthalmol. 1987. PMID: 3580344 Free PMC article.
-
Contact lenses.Br Med J (Clin Res Ed). 1984 Feb 25;288(6417):586-8. doi: 10.1136/bmj.288.6417.586. Br Med J (Clin Res Ed). 1984. PMID: 6421390 Free PMC article. Review. No abstract available.
-
How to promote and preserve eyelid health.Clin Ophthalmol. 2012;6:1689-98. doi: 10.2147/OPTH.S33133. Epub 2012 Oct 25. Clin Ophthalmol. 2012. PMID: 23118519 Free PMC article.
-
Blinking kinematics characterization during digital displays use.Graefes Arch Clin Exp Ophthalmol. 2022 Apr;260(4):1183-1193. doi: 10.1007/s00417-021-05490-9. Epub 2021 Nov 15. Graefes Arch Clin Exp Ophthalmol. 2022. PMID: 34779906 Free PMC article.
-
Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system.Int J Ophthalmol. 2013 Oct 18;6(5):584-7. doi: 10.3980/j.issn.2222-3959.2013.05.05. eCollection 2013. Int J Ophthalmol. 2013. PMID: 24195029 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical