Haemodialysis-induced leucopenia and activation of complement: effects of different membranes
- PMID: 740661
Haemodialysis-induced leucopenia and activation of complement: effects of different membranes
Abstract
The effects on neutrophil count and complement activity of five different haemodialysis membranes were studied. There was no correlation between the degree of neutropenia and intensity of complement activation. With cuprophan membrane both occurred simultaneously but to unrelated degrees; polyacronitrile induced mild, not significant neutropenia but marked activation of complement; polycarbonate membranes induced severe neutropenia without detectable complement activation. Where complement activation occurred it was via the alternative pathway. Haemodialysis induced neutropenia may have many causes and complement activation is probably not the major responsible factor.
Similar articles
-
Leucopenia, hypoxia and complement activation in haemodialysis. Three unrelated phenomena.Proc Eur Dial Transplant Assoc. 1983;19:159-67. Proc Eur Dial Transplant Assoc. 1983. PMID: 6878230
-
Complement activation and leucopenia on cellulosic haemodialyzers: influence of the membrane area and role of hydroxyl moieties.Life Support Syst. 1987 Oct-Dec;5(4):317-22. Life Support Syst. 1987. PMID: 3501504
-
[Comparison of biocompatibility of hemophane, cellulose diacetate and acrilonitile membranes in hemodialysis].Acta Med Croatica. 2004;58(1):31-6. Acta Med Croatica. 2004. PMID: 15125391 Croatian.
-
[Interaction between blood and dialysis membrane].Polim Med. 1991;21(3-4):3-13. Polim Med. 1991. PMID: 1822594 Review. Polish.
-
Complement activation as index of haemodialysis membrane biocompatibility: the choice of methods and assays.Nephrol Dial Transplant. 1994;9 Suppl 2:96-103. Nephrol Dial Transplant. 1994. PMID: 8065623 Review. No abstract available.
Cited by
-
Critical care in uraemic children.Pediatr Nephrol. 1992 Jan;6(1):88-95. doi: 10.1007/BF00856850. Pediatr Nephrol. 1992. PMID: 1536749 Review.
-
The lungs in uraemia: a review.J R Soc Med. 1985 Oct;78(10):849-55. doi: 10.1177/014107688507801012. J R Soc Med. 1985. PMID: 3930725 Free PMC article. Review. No abstract available.
-
Inert gas analysis of ventilation-perfusion matching during hemodialysis.J Clin Invest. 1984 May;73(5):1385-91. doi: 10.1172/JCI111342. J Clin Invest. 1984. PMID: 6715542 Free PMC article.
-
Measuring Circulating Complement Activation Products in Myeloperoxidase- and Proteinase 3-Antineutrophil Cytoplasmic Antibody-Associated Vasculitis.Arthritis Rheumatol. 2019 Nov;71(11):1894-1903. doi: 10.1002/art.41011. Epub 2019 Oct 8. Arthritis Rheumatol. 2019. PMID: 31215772 Free PMC article.
-
Hypoxemia during hemodialysis.J Natl Med Assoc. 1984 Jun;76(6):627-9. J Natl Med Assoc. 1984. PMID: 6748107 Free PMC article.