Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1980 Jun:(149):283-90.

Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci

  • PMID: 7408313

Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci

H Kurosawa et al. Clin Orthop Relat Res. 1980 Jun.

Abstract

The load-bearing mode of the knee joint and the load-carrying capacity of the menisci were investigated by a load-deflection and load-contact study using stresses of as much as 3 times body weight on 14 freshly amputated knee specimens. A flection angle of 0 degrees was used. The average deflection and the average size of the contact area of the intact knees were 1.04 x 10(-1) cm and 14.1 cm2 respectively when the knees were loaded to 1,500 N. The elastic modulus of the entire joint was 2.7 x 10(2) MPa over the load of 1,500 N. At first, the knee joint was not congruous at a low load under about 500 N; the joint contacts both menisci in conjunction with some part of the exposed cartilage. However, the joint became markedly congruous at higher loads, around 1,000 N. The joint was in contact with the menisci and the exposed cartilage, and as more load was applied, the areas of contact widened to the peripheral areas of both the compartments. After menisci were removed, the deflection increased. The size of the contact areas decreased significantly by a third to a half. Consequently, the average stress increased 2 to 3 times that of the intact knee. The elastic modulus was increased over 2 fold after menisci were removed. The results of the energy study indicate that the menisci gave more elastic stability to the joint. After the menisci were removed, more energy was dissipated during cyclic loading. Thus, the menisci provide surface compliance and serve to transmit stresses across the wider areas to the periphery, and, therefore, help to avoid stress concentration both in the articular cartilage and in the subchondral bone, especially under high loads over 1,000 N.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources