Prediction of hemispheric blood flow from carotid velocity measurements. A study with the Doppler and 133Xe inhalation techniques
- PMID: 7414669
- DOI: 10.1161/01.str.11.4.399
Prediction of hemispheric blood flow from carotid velocity measurements. A study with the Doppler and 133Xe inhalation techniques
Abstract
Doppler carotid velocity determinations were related to hemispheric blood flow measurements by the 133Xe inhalation method in 28 patients with psychiatric disorders without arterial pathology and in 2 normal subjects. Results from 39 double determinations showed a product-moment correlation of 0.88 (p < 0.001) between right hemispheric blood flow and right internal carotid end-diastolic velocity. The correlation for the left side was slightly lower (r = 0.83), while the common carotid end-diastolic velocity showed a considerably lower correlation of 0.71 (rt) and 0.69 (lt) respectively. The peak-systolic velocity values (internal carotids) showed a less close relationship to hemispheric flow (r = 0.71 (rt) and r = 0.61 (lt)). It is concluded that a fairly accurate (15-20% maximum error) prediction of hemispheric blood flow from Doppler internal carotid end-diastolic velocity values is possible in patients without abnormalities in these arterial systems. The high correlations found, in spite of the fact that arterial diameters were not taken into account, are further proof of the accuracy and validity of both methods.
Similar articles
-
Derivation of systolic time intervals from Doppler measurement of temporal arterial blood flow.Am J Cardiol. 1981 Jan;47(1):68-72. doi: 10.1016/0002-9149(81)90291-5. Am J Cardiol. 1981. PMID: 7457410
-
Nonstenotic internal carotid arteries: effects of age and blood pressure at the time of scanning on Doppler US velocity measurements.Radiology. 2001 Jul;220(1):174-8. doi: 10.1148/radiology.220.1.r01jl33174. Radiology. 2001. PMID: 11425992 Clinical Trial.
-
Cerebral blood flow in the newborn infant: comparison of Doppler ultrasound and 133xenon clearance.J Pediatr. 1984 Mar;104(3):411-8. doi: 10.1016/s0022-3476(84)81108-7. J Pediatr. 1984. PMID: 6707797
-
Doppler ultrasound in the evaluation of the peripheral arterial circulation.Angiology. 1979 Aug;30(8):526-38. doi: 10.1177/000331977903000803. Angiology. 1979. PMID: 157090 Review.
-
Joint recommendations for reporting carotid ultrasound investigations in the United Kingdom.Eur J Vasc Endovasc Surg. 2009 Mar;37(3):251-61. doi: 10.1016/j.ejvs.2008.10.015. Epub 2008 Nov 29. Eur J Vasc Endovasc Surg. 2009. PMID: 19046904 Review.
Cited by
-
Clinical diagnosis by transcutaneous Doppler ultrasound.Postgrad Med J. 1982 Apr;58(678):197-211. doi: 10.1136/pgmj.58.678.197. Postgrad Med J. 1982. PMID: 7050948 Free PMC article. Review.
-
Blood velocity and regional blood flow in defined cerebral artery systems.Acta Neurochir (Wien). 1989;97(1-2):47-52. doi: 10.1007/BF01577739. Acta Neurochir (Wien). 1989. PMID: 2785744
-
Transcranial Doppler: response of cerebral blood-flow velocity to carbon dioxide in anaesthetized children.Can J Anaesth. 1991 Jan;38(1):37-42. doi: 10.1007/BF03009161. Can J Anaesth. 1991. PMID: 1899204 Clinical Trial.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources