Comparative multicentre trial of three IUDs inserted immediately following delivery of the placenta
- PMID: 7418410
- DOI: 10.1016/0010-7824(80)90112-2
Comparative multicentre trial of three IUDs inserted immediately following delivery of the placenta
Abstract
A multinational comparative trial of three IUDs (Copper 7, Lippes loop size D and the Postpartum T) randomly inserted immediately following delivery of the placenta was conducted in six centres. A total of 841 women entered the study. As the predetermined termination indices for expulsions were exceeded at six months the trial was prematurely closed. An excess of expulsions during the first 48 hours following insertion was observed for the Lippes loop compared to the other devices. At six months the expulsion rate for the Lippes loop was significantly higher than that for the Copper 7. In addition, the discontinuation rate for the Lippes loop at 12 months was significantly higher than that for the Copper 7. There were no significant differences in either the expulsion rates or the discontinuation rate at six or twelve months between the postpartum T and the other devices. At 12 months the pregnancy rates with all three devices was high; there were no ectopic pregnancies. Considerable between-centre differences were observed, particularly for expulsion rates. Possible reasons for this are discussed and future research lines are suggested.
PIP: A multinational comparative of 3 IUDs (Copper 7, Lippes Loop D, and the Postpartum T) randomly inserted immediately following delivery of the placenta was conducted in 6 centers with a total of 841 women participating in the study. As the predetermined termination indices for expulsions were exceded at 6 months, the trial was prematurely closed. An excess of expulsions during the first 48 hours following insertion was observed for the Lippes Loop compared to the other devices. At 6 months the expulsion rate for the Lippes Loop was significantly higher than that for the Copper 7. There were no significant differences in either the expulsion rates or the discontinuation rate at 6 or 12 months between the Postpartum T and the other devices. At 12 months the pregnancy rates with all 3 devices were high; there were no ectopic pregnancies. Considerable between-center differences were observed, particularly for expulsion rates. Possible reasons for this are discussed and future research lines are suggested.
Similar articles
-
Immediate postplacental insertion of GYNE-T 380 and GYNE-T 380 postpartum intrauterine contraceptive devices: randomized study.Am J Obstet Gynecol. 1996 Nov;175(5):1231-5. doi: 10.1016/s0002-9378(96)70033-9. Am J Obstet Gynecol. 1996. PMID: 8942493 Clinical Trial.
-
Interval iud insertion in parous women: a randomized multicentre comparative trial of the Lippes Loop D, TCu220c and the Copper 7.Contraception. 1982 Jul;26(1):1-22. doi: 10.1016/0010-7824(82)90167-6. Contraception. 1982. PMID: 7128130 Clinical Trial.
-
Clinical performance of the TCu 380A and Lippes Loop IUDs in three developing countries.Contraception. 1995 Jul;52(1):17-22. doi: 10.1016/0010-7824(95)00119-u. Contraception. 1995. PMID: 8521710 Clinical Trial.
-
Effectiveness of IUDs: a review.Contraception. 1987 Jul;36(1):55-84. doi: 10.1016/0010-7824(87)90061-8. Contraception. 1987. PMID: 3311626 Review.
-
Quantitative studies on menstrual blood loss in IUD users.Contraception. 1987 Jul;36(1):129-44. doi: 10.1016/0010-7824(87)90065-5. Contraception. 1987. PMID: 3311622 Review.
Cited by
-
Considerations on a new, frameless copper-releasing intrauterine system for intracesarean insertion and its future clinical significance: A review.J Turk Ger Gynecol Assoc. 2020 Jun 8;21(2):130-133. doi: 10.4274/jtgga.galenos.2020.2020.0003. J Turk Ger Gynecol Assoc. 2020. PMID: 32517439 Free PMC article.
-
U.S. Medical Eligibility Criteria for Contraceptive Use, 2024.MMWR Recomm Rep. 2024 Aug 8;73(4):1-126. doi: 10.15585/mmwr.rr7304a1. MMWR Recomm Rep. 2024. PMID: 39106314 Free PMC article.
-
Immediate postpartum insertion of intrauterine device for contraception.Cochrane Database Syst Rev. 2015 Jun 26;2015(6):CD003036. doi: 10.1002/14651858.CD003036.pub3. Cochrane Database Syst Rev. 2015. PMID: 26115018 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials