Polyvinyl alcohol as a protective coating on intraocular lenses
- PMID: 7425911
- DOI: 10.1001/archopht.1980.01020040692019
Polyvinyl alcohol as a protective coating on intraocular lenses
Abstract
Sixty-eight intraocular lenses were implanted in cats to compare the efficacy of a new polyvinyl alcohol coating in protecting the corneal endothelium from lens-cell contact damage. The mean endothelial density after implantation of the coated lens was significantly higher than the cell density in those eyes receiving the uncoated lens. We saw no clinical signs of unusual inflammation; whole-eye histopathologic study disclosed no signs of inflammation or toxicity related to the coating. Ten coated lenses were placed in balanced salt solution or perfused with balanced salt solution at 0.5 mL/min. The coating remained intact for 60 minutes, affording corneal endothelial protection for this period. In a rabbit anterior chamber toxicity study, using balanced salt solution as a control, no differencs in reaction in the anterior chamber or intraocular pressure were noted.
Similar articles
-
[Protection of corneal endothelium during intraocular lens (iridocapsular lens) implantation (author's transl)].Nippon Ganka Gakkai Zasshi. 1980;84(3):252-6. Nippon Ganka Gakkai Zasshi. 1980. PMID: 7386318 Japanese. No abstract available.
-
Corneal endothelial loss with new intraocular lenses.Am J Ophthalmol. 1984 Aug 15;98(2):157-65. doi: 10.1016/0002-9394(87)90350-3. Am J Ophthalmol. 1984. PMID: 6476043
-
Intraocular lens implantation in cats.Ann Ophthalmol. 1981 Aug;13(8):975-7. Ann Ophthalmol. 1981. PMID: 7294639
-
Posterior chamber lens implantation.Int Ophthalmol Clin. 1982 Summer;22(2):135-53. doi: 10.1097/00004397-198202220-00009. Int Ophthalmol Clin. 1982. PMID: 7045004 Review. No abstract available.
-
Mechanical and design considerations in lens implantation.Int Ophthalmol Clin. 1982 Summer;22(2):203-26. doi: 10.1097/00004397-198202220-00013. Int Ophthalmol Clin. 1982. PMID: 7045008 Review. No abstract available.
Cited by
-
Polymeric Implants for the Treatment of Intraocular Eye Diseases: Trends in Biodegradable and Non-Biodegradable Materials.Pharmaceutics. 2021 May 12;13(5):701. doi: 10.3390/pharmaceutics13050701. Pharmaceutics. 2021. PMID: 34065798 Free PMC article. Review.
-
Methane plasma as a protective coating on intraocular lenses: an in vitro study.Int Ophthalmol. 1989 Sep;13(5):357-60. doi: 10.1007/BF02279873. Int Ophthalmol. 1989. PMID: 2625384
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous