Computer-assisted electrocoagulation: bipolar vs. monopolar in the treatment of experimental canine gastric ulcer bleeding
- PMID: 7450440
Computer-assisted electrocoagulation: bipolar vs. monopolar in the treatment of experimental canine gastric ulcer bleeding
Abstract
A prospective, randomized, controlled experiment using a canine model of severely bleeding gastric ulcer was performed to compare the hemostatic efficacy and tissue damage produced by one bipolar and two monopolar electrodes. Both monopolar electrodes were insulated to their tips; they differed with respect to their surface area (3 mm2 vs. 4 mm2). The force of electrode application was controlled. An analog computer monitored the energy per electrode application and predetermined the duration of each application. Fifty-nine standard acute bleeding ulcers were made and treated one at a time in six heparinized foxhounds at sterile laparotomy. Treatment was randomized to the bipolar or to one of the monopolar electrodes within each of three bleeding strata. No significant difference was observed in hemostatic efficacy among the three electrodes. Treated ulcers were examined histologically after 5 to 7 days to determine the maximum tissue damage produced: Bipolar electrocoagulation caused significantly less damage than electrocoagulation with either monopolar electrode. We conclude that with these electrodes, bipolar electrocoagulation is equally effective for stopping bleeding but results in less tissue injury than monopolar electrocoagulation in this experimental model.
Similar articles
-
Comparative study of the safety and efficacy of liquid and dry monopolar electrocoagulation in experimental canine bleeding ulcers using computerized energy monitoring.Gastroenterology. 1984 Jan;86(1):93-103. Gastroenterology. 1984. PMID: 6605892
-
Comparison of endoscopic electrocoagulation and laser photocoagulation of bleeding canine gastric ulcers.Gastroenterology. 1982 May;82(5 Pt 1):904-10. Gastroenterology. 1982. PMID: 7060912 Clinical Trial.
-
Electrosurgical treatment of experimental bleeding canine gastric ulcers: development and testing of a computer control and a better electrode.Gastroenterology. 1978 Mar;74(3):527-34. Gastroenterology. 1978. PMID: 631482 No abstract available.
-
Therapeutic endoscopy and bleeding ulcers. Bipolar/multipolar electrocoagulation.Gastrointest Endosc. 1990 Sep-Oct;36(5 Suppl):S38-41. Gastrointest Endosc. 1990. PMID: 2242810 Review. No abstract available.
-
Therapeutic endoscopy and bleeding ulcers.Natl Inst Health Consens Dev Conf Consens Statement. 1989 Mar 6-8;7(6):1-7. Natl Inst Health Consens Dev Conf Consens Statement. 1989. PMID: 2677688 Review. No abstract available.
Cited by
-
Perforated duodenal ulcer and cigarette smoking.J R Soc Med. 1988 Feb;81(2):92-4. doi: 10.1177/014107688808100214. J R Soc Med. 1988. PMID: 3346864 Free PMC article.
-
Ultracision Harmonic Scalpel and multifunctional tem400 instrument complement in transanal endoscopic microsurgery: a prospective study.Surg Endosc. 2004 Dec;18(12):1730-7. doi: 10.1007/s00464-003-9331-2. Epub 2004 Oct 26. Surg Endosc. 2004. PMID: 15809779 Clinical Trial.
-
Endoscopic hemostasis using laser photocoagulation and electrocoagulation.Dig Dis Sci. 1981 Jul;26(7 Suppl):31S-40S. doi: 10.1007/BF01300804. Dig Dis Sci. 1981. PMID: 6821288 Review. No abstract available.
-
Endoscopic laser treatment of vascular anomalies of the upper gastrointestinal tract.Gut. 1985 Dec;26(12):1338-48. doi: 10.1136/gut.26.12.1338. Gut. 1985. PMID: 3878817 Free PMC article.
-
Bipolar electrocoagulation versus Nd-YAG laser photocoagulation for upper gastrointestinal bleeding lesions.Dig Dis Sci. 1986 Sep;31(9):906-10. doi: 10.1007/BF01303209. Dig Dis Sci. 1986. PMID: 3488184 Clinical Trial.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources