Transthoracic resistance in human defibrillation. Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure
- PMID: 7460251
- DOI: 10.1161/01.cir.63.3.676
Transthoracic resistance in human defibrillation. Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure
Abstract
Successful defibrillation depends on delivery of adequate electrical current to the heart; one of the major determinants of current flow is transthoracic resistance (TTR). To study the factors influencing TTR, we prospectively collected data from 44 patients undergoing emergency defibrillation. Shocks of 94-450 J delivered energy were administered from specially calibrated Datascope defibrillators that displayed peak current flow, thereby permitting determination of TTR. Shocks were applied from standard (8.5-cm diameter) or large (13 cm) paddles placed anteriorly and laterally. First-shock TTR ranged from 15-143 omega. There was a weak correlation between TTR and body weight (r = 0.45, p less than 0.05) and a stronger correlation between TTR and chest width (r = 0.80, p less than 0.01). Twenty-three patients who were defibrillated using standard 8.5-cm paddles had a mean TTR of 67 +/- 36 omega (+/- SD), whereas 21 patients who received shocks using paddle pairs with at least one large (13 cm) paddle had a 21% lower TTR of 53 +/- 24 omega (p = 0.05, unpaired t test). Ten patients received first and second shocks at the same energy level; TTR declined only 8%, from 52 +/- 19 to 48 +/- 16 omega (p less than 0.01, paired t test). In closed chest dogs, shocks were administered using a spring apparatus that regulated paddle contact pressure against the thorax. Firmer contact pressure caused TTR to decrease 25%, from 48 +/- 22 to 36 +/- 17 omega (p less than 0.01, paired t test). Thus, human TTR varies widely and is related most closely to chest size. TTR declines only slightly with a second shock at the same energy level. More substantial reductions in TTR and declines only slightly with a second shock at the same energy level. More substantial reductions in TTR and increases in current flow can be achieved by using large paddles and applying firm paddle contact pressure.
Similar articles
-
Pediatric defibrillation: current flow is improved by using "adult" electrode paddles.Pediatrics. 1994 Jul;94(1):90-3. Pediatrics. 1994. PMID: 8008545
-
Determinants of successful transthoracic defibrillation and outcome in ventricular fibrillation.Br Heart J. 1991 Jun;65(6):311-6. doi: 10.1136/hrt.65.6.311. Br Heart J. 1991. PMID: 2054239 Free PMC article.
-
Effectiveness of direct current defibrillation: role of paddle electrode size.Am Heart J. 1977 Apr;93(4):463-7. doi: 10.1016/s0002-8703(77)80409-2. Am Heart J. 1977. PMID: 842442
-
Overlapping sequential pulses. A new waveform for transthoracic defibrillation.Circulation. 1994 May;89(5):2369-79. doi: 10.1161/01.cir.89.5.2369. Circulation. 1994. PMID: 8181163
-
Transthoracic cardioversion of atrial fibrillation and flutter: standard techniques and new advances.Am J Cardiol. 1996 Oct 17;78(8A):22-6. doi: 10.1016/s0002-9149(96)00562-0. Am J Cardiol. 1996. PMID: 8903272 Review.
Cited by
-
Successful external cardioversion of atrial fibrillation in patients referred to an electrophysiologist for internal cardioversion.Clin Cardiol. 2001 Jul;24(7):500-2. doi: 10.1002/clc.4960240716. Clin Cardiol. 2001. PMID: 11444640 Free PMC article.
-
Randomised comparison of electrode positions for cardioversion of atrial fibrillation.Heart. 1999 Jun;81(6):576-9. doi: 10.1136/hrt.81.6.576. Heart. 1999. PMID: 10336913 Free PMC article. Clinical Trial.
-
Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations.Pediatrics. 2010 Nov;126(5):e1261-318. doi: 10.1542/peds.2010-2972A. Epub 2010 Oct 18. Pediatrics. 2010. PMID: 20956433 Free PMC article. No abstract available.
-
Rate of conversion and recurrence after sotalol treatment in patients with direct current-refractory atrial fibrillation.Clin Cardiol. 2006 Feb;29(2):56-60. doi: 10.1002/clc.4960290204. Clin Cardiol. 2006. PMID: 16506639 Free PMC article.
-
Pad size, orientation, and placement for defibrillation during basic life support: A systematic review.Resusc Plus. 2025 Jul 14;25:101030. doi: 10.1016/j.resplu.2025.101030. eCollection 2025 Sep. Resusc Plus. 2025. PMID: 40741375 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous