[Anatomy of the circle of Willis with 3D time of flight magnetic resonance angiography and analysis of partitions]
- PMID: 7473397
[Anatomy of the circle of Willis with 3D time of flight magnetic resonance angiography and analysis of partitions]
Abstract
The purpose of this study was to analyse with 3D TOF MR angiography the anatomical variants of the circle of Willis (CW) in 109 consecutive patients. In all cases, the quality of exams was sufficient to analyse the anatomy of CW. Nevertheless, MRA over estimated hypoplastic segments because incomplete CW were more frequently demonstrated with MRA than in anatomic literature. This lack of MRA sensitivity was related to artifacts as MIP artifacts and blood flow artifacts. MRA sensitivity was improved by analysis of partitions with MIP reconstructions.
Similar articles
-
Atherosclerotic disease distribution in carotid and vertebrobasilar arteries: clinical experience in 100 patients undergoing fluoro-triggered 3D Gd-MRA.J Magn Reson Imaging. 2003 May;17(5):545-58. doi: 10.1002/jmri.10288. J Magn Reson Imaging. 2003. PMID: 12720264
-
[Diagnosis of renal artery stenosis with magnetic resonance angiography and stenosis quantification].J Mal Vasc. 2000 Dec;25(5):312-320. J Mal Vasc. 2000. PMID: 11148391 Review. French.
-
Circle of Willis: morphologic variation on three-dimensional time-of-flight MR angiograms.Radiology. 1998 Apr;207(1):103-11. doi: 10.1148/radiology.207.1.9530305. Radiology. 1998. PMID: 9530305
-
Effects of RF inhomogeneity at 3.0T on ramped RF excitation: application to 3D time-of-flight MR angiography of the intracranial arteries.J Magn Reson Imaging. 2007 Mar;25(3):466-72. doi: 10.1002/jmri.20832. J Magn Reson Imaging. 2007. PMID: 17279502
-
Pentagon Inside the Circle of Willis and the Golden Ratio.World Neurosurg. 2021 Dec;156:23-26. doi: 10.1016/j.wneu.2021.09.006. Epub 2021 Sep 8. World Neurosurg. 2021. PMID: 34508906 Review.
Cited by
-
Assessment of the collateral function of the circle of Willis: three-dimensional time-of-flight MR angiography compared with transcranial color-coded duplex sonography.AJNR Am J Neuroradiol. 2003 Mar;24(3):456-62. AJNR Am J Neuroradiol. 2003. PMID: 12637297 Free PMC article.
-
Posterior circulation ischemia in patients with fetal-type circle of Willis and hypoplastic vertebrobasilar system.Neurol Sci. 2011 Dec;32(6):1143-6. doi: 10.1007/s10072-011-0763-5. Epub 2011 Sep 17. Neurol Sci. 2011. PMID: 21927884
-
Magnetic resonance angiographic evaluation of circle of Willis: A morphologic study in a tertiary hospital set up.Ann Indian Acad Neurol. 2015 Oct-Dec;18(4):391-7. doi: 10.4103/0972-2327.165453. Ann Indian Acad Neurol. 2015. PMID: 26713008 Free PMC article.