Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
- PMID: 7493856
- DOI: 10.1016/0360-3016(95)00116-6
Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
Abstract
Purpose: Knowledge about the mobility of organs relative to the bony anatomy is of great importance when preparing and verifying conformal radiotherapy. The conventional technique for measuring the motion of an organ is to locate landmarks on the organ and the bony anatomy and to compare the distance between these landmarks on subsequent computerized tomography (CT) scans. The first purpose of this study is to investigate the use of a three dimensional (3D) image registration method based on chamfer matching for measurement of the location and orientation of the whole organ relative to the bony anatomy. The second purpose is to quantify organ motion during conformal therapy of the prostate.
Methods and materials: Four CT scans were made during the course of conformal treatment of 11 patients with prostate cancer. With the use of a 3D treatment planning system, the prostate and seminal vesicles were contoured interactively. In addition, bladder and rectum were contoured and the volume computed. Next, the bony anatomy of subsequent scans was segmented and matched automatically on the first scan. The femora and the pelvic bone were matched separately to quantify motion of the legs. Prostate (and seminal vesicle) contours from the subsequent scans were matched on the corresponding contours of the first scan, resulting in the 3D rotations and translations that describe the motion of the prostate and seminal vesicles relative to the pelvic bone.
Results: Bone matching of two scans with about 50 slices of 256 x 256 pixels takes about 2 min on a workstation and achieves subpixel registration accuracy. Matching of the organ contours takes about 30 s. The accuracy in determining the relative movement of the prostate is 0.5 to 0.9 mm for translations (depending on the axis) and 1 degree for rotations (standard deviations). Because all organ contours are used for matching, small differences in delineation of the prostate, missing slices, or differences in slice distance have only a limited influence on the accuracy. Rotations of the femora and the pelvic bone are quantified with about 0.4 degree accuracy. A strong correlation was found between rectal volume and anterior-posterior translation and rotation around the left-right axis of the prostate. Consequently, these parameters had the largest standard deviations of 2.7 mm and 4.0 degrees. Bladder filling had much less influence. Less significant correlations were found between various leg rotations and pelvic and prostate motion. Standard deviations of the rotation angles of the pelvic bone were less than 1 degree in all directions.
Conclusions: Using 3D image registration, the motion of organs relative to bony anatomy has been quantified accurately. Uncertainties in contouring and visual interpretation of the scans have a much smaller influence on the measurement of organ displacement with our new method than with conventional methods. We have quantified correlations between rectal filling, leg motions, and prostate motion.
Similar articles
-
Quantification and predictors of prostate position variability in 50 patients evaluated with multiple CT scans during conformal radiotherapy.Radiother Oncol. 1999 Feb;50(2):225-34. doi: 10.1016/s0167-8140(99)00011-0. Radiother Oncol. 1999. PMID: 10368047
-
Strategies to reduce the systematic error due to tumor and rectum motion in radiotherapy of prostate cancer.Radiother Oncol. 2005 Feb;74(2):177-85. doi: 10.1016/j.radonc.2004.12.010. Radiother Oncol. 2005. PMID: 15734206 Clinical Trial.
-
Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy.Int J Radiat Oncol Biol Phys. 2005 Jan 1;61(1):228-38. doi: 10.1016/j.ijrobp.2004.09.023. Int J Radiat Oncol Biol Phys. 2005. PMID: 15629616
-
Seminal vesicle inter- and intra-fraction motion during radiotherapy for prostate cancer: A review.Radiother Oncol. 2022 Apr;169:15-24. doi: 10.1016/j.radonc.2022.02.002. Epub 2022 Feb 11. Radiother Oncol. 2022. PMID: 35157975 Review.
-
Trans-anorectal curved linear-array endoscopic ultrasound: Comprehensive pictorial guide (with videos).Dig Endosc. 2025 Jun 3. doi: 10.1111/den.15057. Online ahead of print. Dig Endosc. 2025. PMID: 40458032 Review.
Cited by
-
Commissioning experience with cone-beam computed tomography for image-guided radiation therapy.J Appl Clin Med Phys. 2007 Jul 17;8(3):21-36. doi: 10.1120/jacmp.v8i3.2354. J Appl Clin Med Phys. 2007. PMID: 17712297 Free PMC article.
-
CT slice index and thickness: impact on organ contouring in radiation treatment planning for prostate cancer.J Appl Clin Med Phys. 2003 Autumn;4(4):365-73. doi: 10.1120/jacmp.v4i4.2511. J Appl Clin Med Phys. 2003. PMID: 14604426 Free PMC article.
-
Evaluation of Image Enhancement Method on Target Registration Using Cone Beam CT in Radiation Therapy.Clin Med Oncol. 2008;2:289-99. doi: 10.4137/cmo.s512. Epub 2008 Mar 28. Clin Med Oncol. 2008. PMID: 21892290 Free PMC article.
-
Changes in rectal volume and prostate localization due to placement of a rectum-emptying tube.Jpn J Radiol. 2009 Jun;27(5):205-12. doi: 10.1007/s11604-009-0323-6. Epub 2009 Jun 25. Jpn J Radiol. 2009. PMID: 19554413
-
Accumulated dose to the rectum, measured using dose-volume histograms and dose-surface maps, is different from planned dose in all patients treated with radiotherapy for prostate cancer.Br J Radiol. 2015 Oct;88(1054):20150243. doi: 10.1259/bjr.20150243. Epub 2015 Jul 24. Br J Radiol. 2015. PMID: 26204919 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical