Abstract
The postoperative standing 51-inch radiographs of 352 total knee arthroplasties were reviewed. The angle formed by the tibial tray to the mechanical axis of the tibia in the coronal plane was measured. The mean deviation from a perpendicular cut to the tibial mechanical axis was not significantly different between tibial cuts made with extramedullary alignment and with intramedullary alignment. With extramedullary alignment, 92% of the cuts were +/- 4 degrees of the ideal 90 degrees cut (perpendicular to the mechanical axis), whereas 94% of the cuts with intramedullary alignment were within 4 degrees of ideal. An analysis of the cuts that erred > or = 4 degrees with intramedullary alignment showed that for the majority the intra-medullary guide rod, if passed down the middle of the tibial shaft in the coronal plane, directly led to the less than ideal cut. In these tibias, bowing deformity in the coronal plane made passage of the intramedullary rod parallel to the tibial mechanical axis impossible.
Similar articles
-
Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty.J Formos Med Assoc. 1998 Aug;97(8):564-8. J Formos Med Assoc. 1998. PMID: 9747068
-
The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2010 Oct;18(10):1334-8. doi: 10.1007/s00167-010-1152-y. Epub 2010 May 8. Knee Surg Sports Traumatol Arthrosc. 2010. PMID: 20454779
-
[Evaluation and analysis of the tibial coronal alignment after total knee replacement with the extramedullary tibial cutting guided by the tibial tubercle and anterior tibial tendon in Chinese patients].Beijing Da Xue Xue Bao Yi Xue Ban. 2016 Apr 18;48(2):351-5. Beijing Da Xue Xue Bao Yi Xue Ban. 2016. PMID: 27080295 Chinese.
-
Extramedullary versus intramedullary tibial alignment technique in total knee arthroplasty: A meta-analysis of randomized controlled trials.Clinics (Sao Paulo). 2015 Oct;70(10):714-9. doi: 10.6061/clinics/2015(10)10. Clinics (Sao Paulo). 2015. PMID: 26598086 Free PMC article. Review.
-
Component alignment in total knee arthroplasty.Instr Course Lect. 2006;55:405-12. Instr Course Lect. 2006. PMID: 16958475 Review.
Cited by
-
Tibia vara affects the aspect ratio of tibial resected surface in female Japanese patients undergoing TKA.Clin Orthop Relat Res. 2013 May;471(5):1465-71. doi: 10.1007/s11999-013-2800-6. Clin Orthop Relat Res. 2013. PMID: 23361931 Free PMC article.
-
Reliable and reproducible technique to mark center of ankle in total knee arthroplasty.J Clin Orthop Trauma. 2015 Jun;6(2):144-6. doi: 10.1016/j.jcot.2015.02.001. Epub 2015 Mar 19. J Clin Orthop Trauma. 2015. PMID: 25983524 Free PMC article.
-
Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2008 Mar;16(3):249-57. doi: 10.1007/s00167-007-0420-y. Epub 2007 Dec 22. Knee Surg Sports Traumatol Arthrosc. 2008. PMID: 18157493
-
Longitudinal shapes of the tibia and femur are unrelated and variable.Clin Orthop Relat Res. 2010 Apr;468(4):1142-8. doi: 10.1007/s11999-009-0984-6. Epub 2009 Jul 22. Clin Orthop Relat Res. 2010. PMID: 19623495 Free PMC article.
-
Extramedullary Tibial Bone Cutting Using Medial Cortical Line in Total Knee Arthroplasty.Knee Surg Relat Res. 2017 Sep 1;29(3):189-194. doi: 10.5792/ksrr.16.023. Knee Surg Relat Res. 2017. PMID: 28854764 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources