Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Jul;16(7):1104-14.
doi: 10.1002/elps.11501601187.

Matrix-assisted laser-desorption/ionization mass spectrometric approaches for the identification of gel-separated proteins in the 5-50 pmol range

Affiliations

Matrix-assisted laser-desorption/ionization mass spectrometric approaches for the identification of gel-separated proteins in the 5-50 pmol range

S D Patterson. Electrophoresis. 1995 Jul.

Abstract

The ability to identify and characterize low picomole quantities of gel-separated proteins has greatly benefited from recent advancements in mass spectrometric analysis methods, particularly peptide-mass search routines. We are investigating the use of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS)) to gain as much mass information as possible from a single gel-separated protein species. This report details results obtained from one-dimensional sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) separations, under nonreducing conditions, of known quantities of three proteins, followed by blotting to Immobilon-CD. Three methods were used to obtain MALDI-MS data from a single blotted protein band: (i) direct MALDI-MS of approximately 10% of the band, (ii) cyanogen bromide (CNBr) cleavage of another approximately 10% of the band, and (iii) enzymatic (endoproteinase Lys-C) digestion of the remaining approximately 70-80% of the band followed by MALDI-MS. At the level of 50 pmol of protein loaded onto the gel, data was obtained from all three approaches. At levels down to 5 pmol of protein loaded onto the gel, MALDI-MS data was obtained from the latter two methods, CNBr and Lys-C digestions, but not direct MALDI-MS. Sufficient peptide masses were obtained from the 5 pmol loads to identify two of the three test proteins using four mass search programs. Only limited peptide mass data was obtained from fetuin, a sialylated glycoprotein with six disulfides and no methionines, but it was identified.

PubMed Disclaimer

LinkOut - more resources