Monitoring the patient's EEG during echo planar MRI
- PMID: 7508375
- DOI: 10.1016/0013-4694(93)90156-p
Monitoring the patient's EEG during echo planar MRI
Abstract
The recording of an EEG while the patient is undergoing magnetic resonance imaging (MRI) data acquisition, as far as we are aware, has not been previously accomplished. By careful selection and arrangement of analog multiplexed cable-telemetry equipment to eliminate both ferrous and RF sources, a stable, readable EEG can be obtained without interfering with the diagnostic quality of the MRI. This arrangement does not cause localized heating or burning at the electrode sites. This technical capability permits more accurate neurophysiological control during the acquisition of echo planar functional MRI studies as well as providing indications of anatomical localization of electrical sources.
Similar articles
-
Electroencephalography during functional echo-planar imaging: detection of epileptic spikes using post-processing methods.Magn Reson Med. 2000 Nov;44(5):791-8. doi: 10.1002/1522-2594(200011)44:5<791::aid-mrm17>3.0.co;2-2. Magn Reson Med. 2000. PMID: 11064414
-
Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact.Phys Med Biol. 2015 Jun 21;60(12):N241-50. doi: 10.1088/0031-9155/60/12/N241. Epub 2015 Jun 4. Phys Med Biol. 2015. PMID: 26041140
-
128-channel cable-telemetry EEG recording system for long-term invasive monitoring.Electroencephalogr Clin Neurophysiol. 1991 Jul;79(1):69-72. doi: 10.1016/0013-4694(91)90158-z. Electroencephalogr Clin Neurophysiol. 1991. PMID: 1713554
-
Long-term electroencephalographic monitoring for diagnosis and management of seizures.Mayo Clin Proc. 1996 Oct;71(10):1000-6. doi: 10.1016/S0025-6196(11)63776-2. Mayo Clin Proc. 1996. PMID: 8820777 Review.
-
EEG monitoring during functional MRI in animal models.Epilepsia. 2007;48 Suppl 4:37-46. doi: 10.1111/j.1528-1167.2007.01240.x. Epilepsia. 2007. PMID: 17767574 Review.
Cited by
-
Localizing Epileptic Foci Using Simultaneous EEG-fMRI Recording: Template Component Cross-Correlation.Front Neurol. 2021 Nov 15;12:695997. doi: 10.3389/fneur.2021.695997. eCollection 2021. Front Neurol. 2021. PMID: 34867704 Free PMC article.
-
Broadly applicable methods for the detection of artefacts in electroencephalography acquired simultaneously with hemodynamic recordings.MethodsX. 2023 Sep 14;11:102376. doi: 10.1016/j.mex.2023.102376. eCollection 2023 Dec. MethodsX. 2023. PMID: 37767154 Free PMC article.
-
Motor planning, imagery, and execution in the distributed motor network: a time-course study with functional MRI.Cereb Cortex. 2008 Dec;18(12):2775-88. doi: 10.1093/cercor/bhn036. Epub 2008 Mar 20. Cereb Cortex. 2008. PMID: 18359777 Free PMC article.
-
Blind Visualization of Task-Related Networks From Visual Oddball Simultaneous EEG-fMRI Data: Spectral or Spatiospectral Model?Front Neurol. 2021 Apr 26;12:644874. doi: 10.3389/fneur.2021.644874. eCollection 2021. Front Neurol. 2021. PMID: 33981283 Free PMC article.
-
Functional magnetic resonance imaging: clinical applications and potential.J Inherit Metab Dis. 1999 Jun;22(4):337-52. doi: 10.1023/a:1005535102667. J Inherit Metab Dis. 1999. PMID: 10407771 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources