Selection of optimal prostate specific antigen cutoffs for early detection of prostate cancer: receiver operating characteristic curves
- PMID: 7525995
- DOI: 10.1016/s0022-5347(17)32300-5
Selection of optimal prostate specific antigen cutoffs for early detection of prostate cancer: receiver operating characteristic curves
Abstract
A prospective clinical trial of prostate cancer screening was conducted at 6 university centers including 6,630 men 50 years old or older who underwent a serum prostate specific antigen (PSA) determination and digital rectal examination. Biopsies were performed if the PSA level was greater than 4.0 ng./ml. (Hybritech Tandem assay) or digital rectal examination was suspicious for cancer. We evaluated the effect on biopsy rate and cancer detection if the cutoff value was shifted from 4.0 to age-specific reference ranges recommended in the literature. In men 50 to 59 years old with normal digital rectal examination findings a decrease from 4.0 to 3.5 ng./ml. would have resulted in a 45% increase in the number of biopsies (39 of 87) and a projected 15% increase in cancer detection. An increase from 4.0 to 4.5 ng./ml. in men 60 to 69 years old would result in 15% fewer biopsies (35 of 238) and would miss 8% of the organ confined tumors (2 of 25). Increasing the cutoff to 6.5 ng./ml. in men 70 years old or older would result in 44% fewer biopsies (70 of 159) and would miss 47% of the organ confined cancers (7 of 15). The number of biopsies performed for each cancer detected with a PSA level of greater than 4.0 ng./ml. remains constant across age groupings, which suggests that the cutoff of 4.0 ng./ml. does not need to be altered in the older men, since it is apparently unaffected by the simultaneously increasing prevalence of benign prostatic hyperplasia and cancer with age. We conclude that a serum PSA concentration of 4.0 ng./ml. should be used as a general guideline for biopsy in all age groups.
Comment in
-
Prostate specific antigen.J Urol. 1994 Dec;152(6 Pt 1):2046-8. doi: 10.1016/s0022-5347(17)32302-9. J Urol. 1994. PMID: 7525997 Clinical Trial. No abstract available.
-
Re: Selection of optimal prostate specific antigen cutoffs for early detection of prostate cancer: receiver operating characteristic curves.J Urol. 1995 Sep;154(3):1145-6. doi: 10.1016/s0022-5347(01)67012-5. J Urol. 1995. PMID: 7543610 No abstract available.
-
Re: Selection of optimal prostate specific antigen cutoffs for early detection of prostate cancer: receiver operating characteristic curves.J Urol. 1996 Apr;155(4):1395-6. doi: 10.1016/s0022-5347(01)66288-8. J Urol. 1996. PMID: 8632594 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous