Clinical evaluation of the slide centrifuge (cytospin) gram's stained smear for the detection of bacteriuria and comparison with the FiltraCheck-UTI and UTIscreen
- PMID: 7532911
- DOI: 10.1093/ajcp/103.3.316
Clinical evaluation of the slide centrifuge (cytospin) gram's stained smear for the detection of bacteriuria and comparison with the FiltraCheck-UTI and UTIscreen
Abstract
The cytospin Gram's stained smear method for the detection of bacteriuria was compared with the FiltraCheck-UTI, the UTIscreen and culture of urine specimens from adult male and female inpatients and outpatients in a tertiary care medical institution. At a level of > or = 10(5) CFU/mL, the sensitivity of all three methods was at least 93% for organisms identified as potential pathogens. Investigation of false-negative screening tests by chart review demonstrated that only 5 of 10 combined misses in this category were clinically significant. At a level of > or = 10(4) CFU/mL, the sensitivity of the cytospin method remained essentially unchanged, whereas that of the FiltraCheck-UTI and the UTIscreen decreased to 89% and 85%, respectively. False positives were most frequent with the FiltraCheck-UTI, which was due in part to the presence of white blood cells in the urine. All three tests performed well in this population of patients.
Similar articles
-
Utility of slide centrifuge gram's stain versus quantitative culture for diagnosis of urinary tract infection.Am J Clin Pathol. 1993 Feb;99(2):132-6. doi: 10.1093/ajcp/99.2.132. Am J Clin Pathol. 1993. PMID: 7679871
-
The slide centrifuge gram stain as a urine screening method.Am J Clin Pathol. 1991 Oct;96(4):454-8. doi: 10.1093/ajcp/96.4.454. Am J Clin Pathol. 1991. PMID: 1716413
-
Rapid detection of insignificant bacteriuria by concomitant use of Lumac system and Gram's stain.Am J Clin Pathol. 1984 Nov;82(5):593-6. doi: 10.1093/ajcp/82.5.593. Am J Clin Pathol. 1984. PMID: 6208776
-
FiltraCheck-UTI, a rapid, disposable system for detection of bacteriuria.J Clin Microbiol. 1987 May;25(5):926-8. doi: 10.1128/jcm.25.5.926-928.1987. J Clin Microbiol. 1987. PMID: 3584428 Free PMC article.
-
Automated methods for detection of bacteriuria.Am J Med. 1983 Jul 28;75(1B):71-8. doi: 10.1016/0002-9343(83)90075-x. Am J Med. 1983. PMID: 6192716 Review.