Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1995 Apr;68(4):1613-20.
doi: 10.1016/S0006-3495(95)80335-8.

Cell volume measured by total internal reflection microfluorimetry: application to water and solute transport in cells transfected with water channel homologs

Affiliations

Cell volume measured by total internal reflection microfluorimetry: application to water and solute transport in cells transfected with water channel homologs

J Farinas et al. Biophys J. 1995 Apr.

Abstract

Total internal reflection (TIR) microfluorimetry was established as a method to measure continuously the volume of adherent cells and applied to measure membrane permeabilities in cells transfected with water channel homologs. Cytosol was labeled with the membrane-impermeant fluorophore calcein. Fluorescence was excited by the TIR evanescent field in a thin section of cytosol (approximately 150 nm) adjacent to the cell-substrate interface. Because cytosolic fluorophore number per cell remains constant, the TIR fluorescence signal should be inversely related to cell volume. For small volume changes in Sf-9 and LLC-PK1 cells, relative TIR fluorescence was nearly equal to inverse relative cell volume; deviations from the ideal were modeled theoretically. To measure plasma membrane osmotic water permeability, Pf, the time course of osmotically induced cell volume change was inferred from the TIR fluorescence signal. LLC-PK1 cells expressing the CHIP28 water channel had an HgCl2-sensitive, threefold increase in Pf compared to nontransfected cells (Pf = 0.0043 cm/s at 10 degrees C). Solute permeability was measured from the TIR fluorescence time course in response to solute gradients. Glycerol permeability in Sf-9 cells expressing the water channel homolog GLIP was (1.3 +/- 0.2) x 10(-5) cm/s (22 degrees C), greater than that of (0.36 +/- 0.04) x 10(-5) cm/s (n = 4, p < 0.05) for control cells, indicating functional expression of GLIP. Water and urea permeabilities were similar in GLIP-expressing and control cells. The TIR method should be applicable to the study of water and solute permeabilities and cell volume regulation in cells of arbitrary shape and size.

PubMed Disclaimer

References

    1. J Cell Biol. 1981 Apr;89(1):141-5 - PubMed
    1. Biophys J. 1993 Jul;65(1):236-42 - PubMed
    1. J Cell Biol. 1985 Apr;100(4):1091-102 - PubMed
    1. J Cell Biol. 1985 Apr;100(4):1334-8 - PubMed
    1. J Cell Biol. 1986 Jun;102(6):2015-22 - PubMed

Publication types

MeSH terms

LinkOut - more resources