Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1995 Apr;5(4):260-6.
doi: 10.1046/j.1469-0705.1995.05040260.x.

Diagnosis of early ectopic pregnancy by measurement of the maternal serum to cul-de-sac fluid beta-hCG ratio

Affiliations
Free article
Comparative Study

Diagnosis of early ectopic pregnancy by measurement of the maternal serum to cul-de-sac fluid beta-hCG ratio

B Hinney et al. Ultrasound Obstet Gynecol. 1995 Apr.
Free article

Abstract

In patients suspected of having an ectopic pregnancy, because of a positive beta-human chorionic gonadotropin (beta-hCG) test and a sonographically undetectable gestational sac, even laparoscopy cannot always achieve a precise diagnosis, when the gestational age is very early. This means that the patient has to be followed by repeated beta-hCG measurements and repeated laparoscopy, which are expensive and inconvenient for the patient. This paper reports on a method that is simple to perform and that will provide the clinician with valuable information about the strong likelihood of a tubal pregnancy when ultrasound and beta-hCG measurements raise the suspicion but are not diagnostic. A prerequisite for this approach is the availability of a minimal volume (1-2 ml) of peritoneal fluid in the pouch of Douglas. A total of 131 patients who had a positive beta-hCG test and an undetectable gestational sac within the uterine cavity and who had a small volume of cul-de-sac fluid were studied. The fluid was obtained transvaginally by means of an ultrasound-guided automatic puncture system. The beta-hCG level was determined in the cul-de-sac fluid and in the maternal serum, for comparison. In two cases with tubal pregnancy, concentrated viscous blood samples were aspirated and beta-hCG concentrations could not be measured for technical reasons. In 129 cases, the ratio of levels of beta-hCG between serum and cul-de-sac fluid could be measured. In 42 out of 44 patients with intrauterine pregnancy, the ratio was greater than unity; in 82 out of 85 patients with a tubal pregnancy, the ratio was less than unity. With this ratio used for detection of tubal pregnancy, the diagnostic sensitivity of the test was 95.4% and the specificity was 95.2%. The positive predictive value was 97.6% and the negative predictive value 91.3%. We conclude from these findings that the measurement of the maternal serum to cul-de-sac fluid beta-hCG ratio facilitated the early diagnosis of an ectopic pregnancy in the Fallopian tube.

PubMed Disclaimer

Comment in

  • Ectopic pregnancy: what's new?
    el Farra K, Grudzinskas JG. el Farra K, et al. Ultrasound Obstet Gynecol. 1995 May;5(5):295-6. doi: 10.1046/j.1469-0705.1995.05050295.x. Ultrasound Obstet Gynecol. 1995. PMID: 7542149 No abstract available.

Publication types

Substances

LinkOut - more resources