Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application
- PMID: 7554645
Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application
Abstract
The new 3-dimensional technique was applied to the radiographs of 141 patients who had received Porous Coated Anatomic total hip prostheses. Values were obtained for the position of the acetabular cup, the 3-dimensional distance and direction of femoral head displacement, and the minimum volume of polyethylene debris produced. Mean age of the patients at the time of replacement was 61 years old; mean followup was 5.6 years (range, 4-7.2 years). Change in the position of the femoral head between initial and long-term followup films was assumed to represent polyethylene wear, and formulas were used to calculate the minimal volume of polyethylene debris produced. The overall rate of 3-dimensional femoral head displacement was 0.264 mm per year, almost twice that usually quoted in the current literature for 2-dimensional linear wear. A significant contribution to this value was made by anterior and posterior displacement. Two-dimensional femoral head displacement (measured in the plane of anteroposterior radiographs) on the same patients was 0.149 mm per year. The mean minimum volume of polyethylene debris produced after 5.6 years was 0.448 cm3 (range, 0.00-2.83 cm3), giving a mean rate of 0.079 cm3 polyethylene debris produced each year. Thirteen patients in this series had radiologic osteolysis and a significantly greater femoral head displacement and polyethylene volumetric wear than those with no osteolysis. Patients with a 32-mm femoral head diameter and a polyethylene linear < 1 cm thick had a significantly greater amount of polyethylene wear. This series gives previously unavailable data on 3-dimensional femoral head displacement and is the first report that correlates the minimum volume of polyethylene wear produced with radiologic osteolysis.
Similar articles
-
Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique.Clin Orthop Relat Res. 1995 Oct;(319):303-16. Clin Orthop Relat Res. 1995. PMID: 7554644
-
Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial.J Bone Joint Surg Am. 1997 May;79(5):682-9. doi: 10.2106/00004623-199705000-00007. J Bone Joint Surg Am. 1997. PMID: 9160940 Clinical Trial.
-
The rates of wear of X3 highly cross-linked polyethylene at five years when coupled with a 36 mm diameter ceramic femoral head in young patients.Bone Joint J. 2015 Nov;97-B(11):1470-4. doi: 10.1302/0301-620X.97B11.35736. Bone Joint J. 2015. PMID: 26530647
-
The rationale for cemented total hip arthroplasty.Orthop Clin North Am. 1993 Oct;24(4):599-610. Orthop Clin North Am. 1993. PMID: 8414425 Review.
-
Correlation of wear debris-induced osteolysis and revision with volumetric wear-rates of polyethylene: a survey of 8 reports in the literature.Acta Orthop Scand. 2001 Feb;72(1):22-8. doi: 10.1080/000164701753606644. Acta Orthop Scand. 2001. PMID: 11327409 Review.
Cited by
-
Toxicological impact of microplastics and nanoplastics on humans: understanding the mechanistic aspect of the interaction.Front Toxicol. 2023 Jul 14;5:1193386. doi: 10.3389/ftox.2023.1193386. eCollection 2023. Front Toxicol. 2023. PMID: 37521752 Free PMC article. Review.
-
Eleven-year results of the ABG I hip replacement.Int Orthop. 2006 Jun;30(3):182-4. doi: 10.1007/s00264-006-0075-1. Epub 2006 Mar 7. Int Orthop. 2006. PMID: 16521011 Free PMC article.
-
Impact of Microplastics and Nanoplastics on Human Health.Nanomaterials (Basel). 2021 Feb 16;11(2):496. doi: 10.3390/nano11020496. Nanomaterials (Basel). 2021. PMID: 33669327 Free PMC article. Review.
-
The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty. A study of validity and reliability.Acta Orthop. 2010 Oct;81(5):570-8. doi: 10.3109/17453674.2010.506632. Acta Orthop. 2010. PMID: 20860443 Free PMC article.
-
Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.HSS J. 2005 Sep;1(1):31-4. doi: 10.1007/s11420-005-0102-6. HSS J. 2005. PMID: 18751806 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources