An experimental study of optimal parameters for bipolar electrocoagulation
- PMID: 7557172
An experimental study of optimal parameters for bipolar electrocoagulation
Abstract
The role of artery diameter, probe force application (94, 250 or 491 g), coagulation time (2, 10, or 20 secs) and BICAP generator output (5, 10) were studied in rabbit arteries of 3 to 5 mm hemicircumference. Arterial welds were then tested to destruction by increasing intraluminal pressure. The best arterial welds were achieved by the highest force and coagulation time; high generator output did not improve weld strength. These in vitro experiments suggest that when treating a bleeding peptic ulcer, BICAP therapy should be done with a low generator output of 5 or less, for at least 20 seconds per site, and with as great a compression force as possible.
Similar articles
-
An experimental study of optimal parameters for bipolar electrocoagulation.Gastrointest Endosc. 1995 Jul;42(1):27-30. doi: 10.1016/S0016-5107(95)70238-5. Epub 2005 Oct 28. Gastrointest Endosc. 1995. PMID: 28140055
-
Determination of the optimal technique for bipolar electrocoagulation treatment. An experimental evaluation of the BICAP and Gold probes.Gastroenterology. 1991 Jan;100(1):107-12. doi: 10.1016/0016-5085(91)90589-d. Gastroenterology. 1991. PMID: 1983812
-
Microwave energy compared with heater probe and BICAP in canine models of peptic ulcer hemorrhage.Gastroenterology. 1989 Sep;97(3):676-84. Gastroenterology. 1989. PMID: 2753328
-
Therapeutic endoscopy and bleeding ulcers. Bipolar/multipolar electrocoagulation.Gastrointest Endosc. 1990 Sep-Oct;36(5 Suppl):S38-41. Gastrointest Endosc. 1990. PMID: 2242810 Review. No abstract available.
-
Therapeutic modalities for treatment of peptic ulcer bleeding.Gastroenterologist. 1997 Mar;5(1):26-40. Gastroenterologist. 1997. PMID: 9074917 Review.
Cited by
-
New bipolar tissue ligator combines constant tissue compression and temperature guidance: histologic study and implications for treatment of hemorrhoids.Med Devices (Auckl). 2012;5:89-96. doi: 10.2147/MDER.S34390. Epub 2012 Oct 16. Med Devices (Auckl). 2012. PMID: 23152714 Free PMC article.
-
Variation in electrosurgical vessel seal quality along the length of a porcine carotid artery.Proc Inst Mech Eng H. 2016 Mar;230(3):169-74. doi: 10.1177/0954411915621092. Epub 2016 Jan 7. Proc Inst Mech Eng H. 2016. PMID: 26743899 Free PMC article.
-
Novel concave-convex electrode for colonic anastomoses by radiofrequency thermo-fusion.Surg Endosc. 2015 Jul;29(7):1809-16. doi: 10.1007/s00464-014-3864-4. Epub 2014 Oct 11. Surg Endosc. 2015. PMID: 25303908
-
Effectiveness of endoclips for the treatment of stigmata of recent hemorrhage in the colon of patients with acute lower gastrointestinal tract bleeding.Dig Dis Sci. 2011 Oct;56(10):2978-86. doi: 10.1007/s10620-011-1683-1. Epub 2011 May 7. Dig Dis Sci. 2011. PMID: 21553169
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources