Evaluation of myocardial ischemia using a rest metabolism/stress perfusion protocol with fluorine-18 deoxyglucose/technetium-99m MIBI and dual-isotope simultaneous-acquisition single-photon emission computed tomography
- PMID: 7560611
- DOI: 10.1016/0735-1097(95)00295-6
Evaluation of myocardial ischemia using a rest metabolism/stress perfusion protocol with fluorine-18 deoxyglucose/technetium-99m MIBI and dual-isotope simultaneous-acquisition single-photon emission computed tomography
Abstract
Objectives: This study sought to develop a dual-isotope single-acquisition single-photon emission computed tomographic (SPECT) protocol using a multihead SPECT camera equipped with an ultra-high energy collimator to evaluate rest metabolism/stress perfusion simultaneously with fluorine-18 (F-18) deoxyglucose/technetium-99m (Tc-99m) 2-hexakis-2-methoxy-2-methylpropyl isonitrile (MIBI).
Background: The most accurate and logistic method of identifying injured but viable myocardium remains a diagnostic challenge.
Methods: Sixty-five patients were given 25 to 50 g of glucose and, after approximately 60 min, an injection of 370 MBq (10 mCi) of F-18 fluorodeoxyglucose. After a 35-min distribution phase, patients underwent exercise or pharmacologic stress followed by administration of 925 MBq (25 mCi) of Tc-99m MIBI. Five patients underwent F-18 fluorodeoxyglucose position emission tomography before dual-isotope SPECT:
Results: With a window of 20% for both photopeaks and a technetium-99m/fluorine-18 concentration of 3.2:1, the "spillover" from fluorine-18 into the technetium-99m window is < 6% of the total counts in the window in patients with a normal distribution of both radiopharmaceuticals. Phantom images clearly demonstrated cardiac defects measuring 2 x 1 and 2 x 0.5 cm. There was no significant difference in the images of the five patients who underwent both positron emission tomography and SPECT: Fifty-seven patients (mean [+/- SD] age 55 +/- 15 years, range 25 to 83; 38 men, 19 women) had satisfactory images and were included in the study. Twenty-one patients had normal study results; 15 had mismatched defects; 14 had matched defects; and 7 had both matched and mismatched defects. Twenty-three patients (mean age 54 +/- 6 years, range 30 to 83; 14 men, 9 women) underwent coronary angiography within 3 months of dual-isotope SPECT: There were seven normal studies, eight with mismatched defects, one with a matched defect and seven with matched and mismatched defects. When stenosis > 70% was used as the criterion for a diagnosis of coronary artery disease, dual-isotope SPECT had a sensitivity of 100%, specificity of 88%, positive predictive value of 93%, negative predictive value of 100% and an accuracy of 96%.
Conclusions: Dual-isotope SPECT may provide an alternative, accurate, cost-effective method to nitrogen-13 ammonia/F-18 fluorodeoxyglucose positron emission tomography or thallium-201 reinjection for identifying injured or dysfunctional but viable myocardium.
Similar articles
-
Rest myocardial perfusion/metabolism imaging using simultaneous dual-isotope acquisition SPECT with technetium-99m-MIBI/fluorine-18-FDG.J Nucl Med. 1995 Nov;36(11):2110-9. J Nucl Med. 1995. PMID: 7472607
-
Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability.Nucl Med Commun. 2003 Mar;24(3):251-7. doi: 10.1097/00006231-200303000-00004. Nucl Med Commun. 2003. PMID: 12612465
-
Myocardial metabolic imaging by means of fluorine-18 deoxyglucose/technetium-99m sestamibi dual-isotope single-photon emission tomography.Eur J Nucl Med. 1994 Oct;21(10):1085-93. doi: 10.1007/BF00181063. Eur J Nucl Med. 1994. PMID: 7828618
-
Fluorine 18-labeled fluorodeoxyglucose myocardial single-photon emission computed tomography: an alternative for determining myocardial viability.J Nucl Cardiol. 1996 Jul-Aug;3(4):342-9. doi: 10.1016/s1071-3581(96)90095-1. J Nucl Cardiol. 1996. PMID: 8799254 Review.
-
The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.Anadolu Kardiyol Derg. 2004 Jun;4(2):161-8. Anadolu Kardiyol Derg. 2004. PMID: 15165953 Review.
Cited by
-
Proceedings of the 4th Invitational Wintergreen Conference. Wintergreen, Virginia, USA. July 12-14, 1998. Abstracts.J Nucl Cardiol. 1999 Jan-Feb;6(1 Pt 1):93-155. J Nucl Cardiol. 1999. PMID: 10223813 No abstract available.
-
Metabolic imaging using F18-fluorodeoxyglucose to assess myocardial viability.Int J Card Imaging. 1997 Apr;13(2):145-55; discussion 157-60. doi: 10.1023/a:1005744810876. Int J Card Imaging. 1997. PMID: 9110194 Review.
-
Collimation approaches to 511-keV imaging.West J Med. 1996 Nov;165(5):305-6. West J Med. 1996. PMID: 8993207 Free PMC article. No abstract available.
-
Imaging techniques in nuclear cardiology for the assessment of myocardial viability.Int J Cardiovasc Imaging. 2006 Feb;22(1):63-80. doi: 10.1007/s10554-005-7514-8. Epub 2005 Dec 13. Int J Cardiovasc Imaging. 2006. PMID: 16372139 Review.
-
Imaging myocardial metabolic remodeling.J Nucl Med. 2010 May 1;51 Suppl 1(Suppl 1):88S-101S. doi: 10.2967/jnumed.109.068197. J Nucl Med. 2010. PMID: 20457796 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources