Clinical Trial
. 1995 Oct;96(4):495-501.
doi: 10.1016/s0091-6749(95)70293-8.

Effect of solution and suspension type aerosol of formoterol on tremor response and airways in patients with asthma

Affiliations
Clinical Trial

Effect of solution and suspension type aerosol of formoterol on tremor response and airways in patients with asthma

K Bauer et al. J Allergy Clin Immunol. 1995 Oct.

Abstract

Background: Aerosol delivery and deposition to the oropharynx and the lungs have been found to be different for solution-type and suspension-type metered-dose aerosols used for treatment of asthma. We investigated possible differences in clinical effects between solution and suspension metered-dose formoterol aerosols.

Methods: A total of 24 patients with asthma (forced expiratory volume in 1 second, < or = 70% predicted) inhaled single doses (12 micrograms or 24 micrograms) of formoterol solution and suspension so that we could investigate the immediate tremor, airway, and cardiovascular responses in a randomized, double-blind, crossover trial. Fenoterol suspension aerosol (400 micrograms) was used for comparison (single-blind, poststudy, nonrandomized administration). Fenoterol (400 micrograms) as a rescue medication was inhaled after 120 minutes on each of the 5 study days.

Results: The order of mean (+/- SEM) maximum tremor acceleration was as follows: 12 micrograms formoterol solution (67.92 +/- 4.54 cm x sec-2) < 24 micrograms solution (73.46 +/- 4.51 cm x sec-2) < 12 micrograms suspension (80.87 +/- 5.08 cm x sec-2) < fenoterol (84.13 +/- 4.21 cm x sec-2) < 24 micrograms formoterol suspension 88.54 +/- 6.26 cm x sec-2). Maximum increase in specific airway conductance ranged from 0.48 +/ 0.03 to 0.55 +/- 0.04 sec-1 x kPa-1 for all drugs (p > 0.05). No change in cardiovascular parameters occurred (p > 0.05).

Conclusion: No difference in the bronchial response to either formulation of formoterol was found. Tremor response to suspension aerosol (24 micrograms > 12 micrograms) was higher than that to solution aerosol (24 micrograms > 12 micrograms), indicating possible differences in systemic absorption because of a different deposition pattern. Rescue medication demonstrated systemic effects on tremor that were additive to those of formoterol.

PubMed Disclaimer

Publication types

MeSH terms